Eaton MPI2510V2-1R5-R 1.5 uH Shielded Inductor 85 mOhm
Eaton MPI2510V2-1R5-R 1.5 uH Shielded Inductor 85 mOhm

Eaton MPI2510V2-1R5-R 1.5 uH Shielded Inductor 85 mOhm

Share
MPI2510V2-1R5-R: high-current power inductor, 1.5 uH, 2.5 A, Isat 65 A, DCR 85 mOhm.
    • Product Details
    • Download

    Eaton MPI2510V2-1R5-R 1.5 uH Shielded Inductor 85 mOhm

    MPI2510V2-1R5-R at a glance: high-current power inductor, 1.5 uH, 2.5 A, Isat 65 A, DCR 85 mOhm.

    Key Specifications

    ParameterValue
    Orderable part numberMPI2510V2-1R5-R
    Inductance1.5 uH ±20%
    DCR maximum @ +25 °C85 mOhm
    Irms (DC, 40 °C rise)2.5 A
    Isat65 A
    SRF typical4695 MHz
    MountingSurface mount
    Operating temperature-40 °C to +125 °C
    QualificationCommercial grade
    RoHSCompliant, -R suffix
    Data sheetEaton Technical Data 10649

    Dimensions and Pad Layout

    MPI2510V2-1R5-R mechanical dimensions and pad layout

    Drawing reproduced from Eaton Technical Data 10649: outline with rated mm dimensions, pad layout and marking. Tolerances are stated on the drawing.

    Reading the Data Sheet

    Power inductors in this family are chosen on three numbers: inductance for the ripple, saturation current for the transient, and DCR for the loss. The data sheet gives all three against a defined test condition, which is what makes the row comparable with parts from other vendors.

    At 2.5 A the winding dissipates about 0.531 W in copper, using the 85 mOhm figure. That is the DC floor of the loss budget: ripple and core loss come on top of it.

    Saturation is reached at 65 A. Beyond that point the inductance falls on the soft part of the curve, and the converter’s ripple grows faster than the load current does.

    Within the MPI2510V2 family this is value 5 of 7, in a range that runs from 0.33 to 3.3 uH.

    What This Family Is For

    The power inductor family covers sub-microhenry to tens of microhenry at currents from a few amps to tens of amps, in shielded surface-mount bodies. The data sheet rows carry both typical and maximum DCR so the loss budget can be built either way.

    • DCR is quoted at +20 °C. Copper resistance rises about 0.4 % per °C, so the hot loss is higher than the cold figure.
    • Typical applications: mobile/smart phones; handheld/mobile equipment; tablets/e-readers; digital cameras; wearable devices.
    • Design note: ripple from OCL, thermal from Irms, transient from Isat. Three different numbers, three different checks.

    Frequently Asked Questions

    Is the part shielded?
    The molded body encloses the winding, so the external field is small enough to place parts side by side on a multiphase rail.

    Is the part shielded?
    The molded body encloses the winding, so the external field is small enough to place parts side by side on a multiphase rail.

    Why are there two DCR columns?
    Typical and maximum. A guaranteed thermal design uses the maximum; a nominal efficiency calculation can use the typical.