| Parameter | Value |
|---|---|
| Orderable part number | MPI2512V2-1R5-R |
| Inductance | 1.5 uH ±20% |
| DCR maximum @ +25 °C | 64 mOhm |
| Irms (DC, 40 °C rise) | 2.3 A |
| Isat | 3.2 A |
| SRF typical | 45 MHz |
| K-factor | 4850 |
| Mounting | Surface mount |
| Operating temperature | -40 °C to +125 °C |
| Qualification | Commercial grade |
| RoHS | Compliant, -R suffix |
| Data sheet | Eaton Technical Data 10649 |

Drawing reproduced from Eaton Technical Data 10649: outline with rated mm dimensions, pad layout and marking. Tolerances are stated on the drawing.
This is a surface-mount power inductor for DC-DC conversion. Its two limiting numbers are Irms, which sets the thermal ceiling, and Isat, which sets the current at which inductance has fallen by a defined percentage – both are on the data sheet row and both matter at different points in the load profile.
At 2.3 A the winding dissipates about 0.339 W in copper, using the 64 mOhm figure. That is the DC floor of the loss budget: ripple and core loss come on top of it.
Saturation is reached at 3.2 A. Beyond that point the inductance falls on the soft part of the curve, and the converter’s ripple grows faster than the load current does.
Within the MPI2512V2 family this is value 5 of 7, in a range that runs from 0.33 to 3.3 uH.
The power inductor family covers sub-microhenry to tens of microhenry at currents from a few amps to tens of amps, in shielded surface-mount bodies. The data sheet rows carry both typical and maximum DCR so the loss budget can be built either way.
Why are there two DCR columns?
Typical and maximum. A guaranteed thermal design uses the maximum; a nominal efficiency calculation can use the typical.
Is the part shielded?
The molded body encloses the winding, so the external field is small enough to place parts side by side on a multiphase rail.
What is the difference between Irms and Isat?
Irms is the DC current that produces the rated temperature rise. Isat is the peak current at which inductance has fallen by a defined percentage. A converter can run above Irms briefly but must stay inside Isat.
Shenzhen Gaorunxin Technology Co., Ltd
Shenzhen Gaorunxin Technology Co., Ltd