MPI4020V2-R22-R: high-current power inductor, 0.22 uH, 13 A, Isat 5.5 A, DCR 6.6 mOhm.
    • Product Details
    • Download

    Eaton MPI4020V2-R22-R 0.22 uH Inductor, Isat 5.5 A

    MPI4020V2-R22-R at a glance: high-current power inductor, 0.22 uH, 13 A, Isat 5.5 A, DCR 6.6 mOhm.

    Electrical Specifications

    ParameterValue
    Orderable part numberMPI4020V2-R22-R
    Inductance0.22 nH ±20%
    DCR maximum @ +25 °C6.6 mOhm
    Irms (DC, 40 °C rise)13 A
    Isat5.5 A
    SRF typical165 MHz
    K-factor2036
    MountingSurface mount
    Operating temperature-55 °C to +125 °C
    QualificationCommercial grade
    RoHSCompliant, -R suffix
    Data sheetEaton Technical Data 10651

    Dimensions and Pad Layout

    MPI4020V2-R22-R mechanical dimensions and pad layout

    Drawing reproduced from Eaton Technical Data 10651: outline with rated mm dimensions, pad layout and marking. Tolerances are stated on the drawing.

    Reading the Data Sheet

    Power inductors in this family are chosen on three numbers: inductance for the ripple, saturation current for the transient, and DCR for the loss. The data sheet gives all three against a defined test condition, which is what makes the row comparable with parts from other vendors.

    At 13 A the winding dissipates about 1.12 W in copper, using the 6.6 mOhm figure. That is the DC floor of the loss budget: ripple and core loss come on top of it.

    Saturation is reached at 5.5 A. Beyond that point the inductance falls on the soft part of the curve, and the converter’s ripple grows faster than the load current does.

    Within the MPI4020V2 family this is value 2 of 16, in a range that runs from 0.1 to 22 uH.

    Positioning in the Range

    The power inductor family covers sub-microhenry to tens of microhenry at currents from a few amps to tens of amps, in shielded surface-mount bodies. The data sheet rows carry both typical and maximum DCR so the loss budget can be built either way.

    • DCR is quoted at +20 °C. Copper resistance rises about 0.4 % per °C, so the hot loss is higher than the cold figure.
    • Typical applications: handheld/mobile devices; portable media players; notebook/netbook/laptop regulators; tablets/smartbooks; battery operated devices.
    • Design note: ripple from OCL, thermal from Irms, transient from Isat. Three different numbers, three different checks.

    Frequently Asked Questions

    Is the part shielded?
    The molded body encloses the winding, so the external field is small enough to place parts side by side on a multiphase rail.

    How much inductance is left at rated current?
    The FLL column gives the inductance at saturation current. Ripple at full load should be calculated with FLL, not with the zero-bias value.

    Why are there two DCR columns?
    Typical and maximum. A guaranteed thermal design uses the maximum; a nominal efficiency calculation can use the typical.