Eaton MPI5451R1-1R5-R 1.5 uH Shielded Power Inductor
Eaton MPI5451R1-1R5-R 1.5 uH Shielded Power Inductor

Eaton MPI5451R1-1R5-R 1.5 uH Shielded Power Inductor

Share
MPI5451R1-1R5-R: automotive power inductor, 1.5 uH , 3.4 A Irms, Isat 6.1 A, DCR 48 mOhm.
    • Product Details
    • Download

    Eaton MPI5451R1-1R5-R 1.5 uH Shielded Power Inductor

    MPI5451R1-1R5-R at a glance: automotive power inductor, 1.5 uH , 3.4 A Irms, Isat 6.1 A, DCR 48 mOhm.

    Specification Table

    ParameterValue
    Orderable part numberMPI5451R1-1R5-R
    Inductance1.5 uH
    DCR typical @ +20 °C48 mOhm
    Irms (DC, 40 °C rise)3.4 A
    Isat6.1 A
    K-factor498
    MountingSurface mount
    Operating temperature-40 °C to +125 °C
    QualificationCommercial grade
    RoHSCompliant, -R suffix
    Data sheetEaton Technical Data 10247

    Mechanical Drawing

    MPI5451R1-1R5-R mechanical dimensions and pad layout

    Drawing reproduced from Eaton Technical Data 10247: outline with
    rated mm dimensions, pad layout and marking.

    What the Numbers Mean

    A molded automotive power inductor with a soft saturation curve: as current rises the inductance droops instead of collapsing, so a converter keeps control through a load step. The body is molded around the winding, which contains the field.

    At 3.4 A the winding dissipates about 0.555 W in copper using the typical DCR of 48 mOhm. That is the DC floor of the loss budget – ripple and core loss come on top.

    The core stores about 27.9 uJ at the saturation point, which is the energy available to bridge a load step.

    The K-factor of 498 converts inductance and ripple into flux swing; read the core-loss curve at that amplitude.

    Within the MPI5451R1 family this is value 4 of 11, in a range from 0.33 uH to 15 uH.

    Series Positioning

    The MPIA family is the automotive miniature power range: AEC-Q200 qualified, low profile, in sizes from 2 mm to 4 mm, with both typical and maximum DCR quoted for every row.

    • DCR is quoted at +20 °C; copper rises about 0.4 % per °C, so the hot loss is higher than the cold figure.
    • Typical applications: handheld/mobile devices; portable media players; mp3 players; battery operated devices; notebook/netbook.
    • Design note: ripple from OCL, thermal from Irms, transient from Isat. Three numbers, three checks.

    Frequently Asked Questions

    Why two DCR columns?
    Typical and maximum. A guaranteed thermal design uses the maximum; a nominal efficiency calculation can use the typical.

    Why two DCR columns?
    Typical and maximum. A guaranteed thermal design uses the maximum; a nominal efficiency calculation can use the typical.

    Is the part shielded?
    The molded body encloses the winding, so the external field is small enough for dense layouts.