Eaton MPI5451R1-R33-R 0.33 uH Inductor, Isat 11.5 A
Eaton MPI5451R1-R33-R 0.33 uH Inductor, Isat 11.5 A

Eaton MPI5451R1-R33-R 0.33 uH Inductor, Isat 11.5 A

Share
MPI5451R1-R33-R: automotive power inductor, 0.33 uH , 6.5 A Irms, Isat 11.5 A, DCR 13 mOhm.
    • Product Details
    • Download

    Eaton MPI5451R1-R33-R 0.33 uH Inductor, Isat 11.5 A

    MPI5451R1-R33-R at a glance: automotive power inductor, 0.33 uH , 6.5 A Irms, Isat 11.5 A, DCR 13 mOhm.

    Specification Table

    ParameterValue
    Orderable part numberMPI5451R1-R33-R
    Inductance0.33 uH
    DCR typical @ +20 °C13 mOhm
    Irms (DC, 40 °C rise)6.5 A
    Isat11.5 A
    K-factor1244
    MountingSurface mount
    Operating temperature-40 °C to +125 °C
    QualificationCommercial grade
    RoHSCompliant, -R suffix
    Data sheetEaton Technical Data 10247

    Mechanical Dimensions & Pad Layout

    MPI5451R1-R33-R mechanical dimensions and pad layout

    Drawing reproduced from Eaton Technical Data 10247: outline with
    rated mm dimensions, pad layout and marking.

    How to Read These Ratings

    A molded automotive power inductor with a soft saturation curve: as current rises the inductance droops instead of collapsing, so a converter keeps control through a load step. The body is molded around the winding, which contains the field.

    At 6.5 A the winding dissipates about 0.549 W in copper using the typical DCR of 13 mOhm. That is the DC floor of the loss budget – ripple and core loss come on top.

    The core stores about 21.8 uJ at the saturation point, which is the energy available to bridge a load step.

    The K-factor of 1244 converts inductance and ripple into flux swing; read the core-loss curve at that amplitude.

    Within the MPI5451R1 family this is value 1 of 11, in a range from 0.33 uH to 15 uH.

    Positioning in the Range

    The MPIA family is the automotive miniature power range: AEC-Q200 qualified, low profile, in sizes from 2 mm to 4 mm, with both typical and maximum DCR quoted for every row.

    • DCR is quoted at +20 °C; copper rises about 0.4 % per °C, so the hot loss is higher than the cold figure.
    • Typical applications: handheld/mobile devices; portable media players; mp3 players; battery operated devices; notebook/netbook.
    • Design note: ripple from OCL, thermal from Irms, transient from Isat. Three numbers, three checks.

    Frequently Asked Questions

    Why two DCR columns?
    Typical and maximum. A guaranteed thermal design uses the maximum; a nominal efficiency calculation can use the typical.

    How much inductance is left at rated current?
    The FLL column gives the inductance at saturation current. Ripple at full load should be calculated with FLL.

    What is the difference between Irms and Isat?
    Irms is the DC current for the rated temperature rise; Isat is the peak current at a defined inductance rolloff. A converter can exceed Irms briefly but must stay inside Isat.

    Shenzhen Gaorunxin Technology Co., Ltd

    Online message

    Shenzhen Gaorunxin Technology Co., Ltd

    Related Products