Eaton MPI5451R3-6R8-R 6.8 uH Power Inductor, 2.6 A
Eaton MPI5451R3-6R8-R 6.8 uH Power Inductor, 2.6 A

Eaton MPI5451R3-6R8-R 6.8 uH Power Inductor, 2.6 A

Share
MPI5451R3-6R8-R: automotive power inductor, 6.8 uH , 2.6 A Irms, Isat 3 A, DCR 70 mOhm.
    • Product Details
    • Download

    Eaton MPI5451R3-6R8-R 6.8 uH Power Inductor, 2.6 A

    MPI5451R3-6R8-R at a glance: automotive power inductor, 6.8 uH , 2.6 A Irms, Isat 3 A, DCR 70 mOhm.

    Ratings at a Glance

    ParameterValue
    Orderable part numberMPI5451R3-6R8-R
    Inductance6.8 uH
    DCR typical @ +20 °C70 mOhm
    Irms (DC, 40 °C rise)2.6 A
    Isat3 A
    K-factor249
    MountingSurface mount
    Operating temperature-40 °C to +125 °C
    QualificationCommercial grade
    RoHSCompliant, -R suffix
    Data sheetEaton Technical Data 10247

    Dimensions and Pad Layout

    MPI5451R3-6R8-R mechanical dimensions and pad layout

    Drawing reproduced from Eaton Technical Data 10247: outline with
    rated mm dimensions, pad layout and marking.

    The Figures Explained

    Power inductors in this family are chosen on three numbers: inductance for ripple, saturation current for the transient, and DCR for loss. The data sheet row gives all three against defined test conditions.

    At 2.6 A the winding dissipates about 0.473 W in copper using the typical DCR of 70 mOhm. That is the DC floor of the loss budget – ripple and core loss come on top.

    The core stores about 30.6 uJ at the saturation point, which is the energy available to bridge a load step.

    The K-factor of 249 converts inductance and ripple into flux swing; read the core-loss curve at that amplitude.

    Within the MPI5451R3 family this is value 8 of 9, in a range from 0.47 uH to 10 uH.

    Series Positioning

    The MPIA family is the automotive miniature power range: AEC-Q200 qualified, low profile, in sizes from 2 mm to 4 mm, with both typical and maximum DCR quoted for every row.

    • DCR is quoted at +20 °C; copper rises about 0.4 % per °C, so the hot loss is higher than the cold figure.
    • Typical applications: handheld/mobile devices; portable media players; mp3 players; battery operated devices; notebook/netbook.
    • Design note: ripple from OCL, thermal from Irms, transient from Isat. Three numbers, three checks.

    Frequently Asked Questions

    How much inductance is left at rated current?
    The FLL column gives the inductance at saturation current. Ripple at full load should be calculated with FLL.

    Why two DCR columns?
    Typical and maximum. A guaranteed thermal design uses the maximum; a nominal efficiency calculation can use the typical.

    Why two DCR columns?
    Typical and maximum. A guaranteed thermal design uses the maximum; a nominal efficiency calculation can use the typical.