MPIA2010V1-1R0-R: automotive power inductor, 1 uH , 3 A Irms, Isat 3 A, DCR 56 mOhm.
    • Product Details
    • Download

    Eaton MPIA2010V1-1R0-R 1 uH Inductor, Isat 3 A

    MPIA2010V1-1R0-R at a glance: automotive power inductor, 1 uH , 3 A Irms, Isat 3 A, DCR 56 mOhm.

    Specification Table

    ParameterValue
    Orderable part numberMPIA2010V1-1R0-R
    Inductance1 uH
    FLL minimum (at Isat)0.56 uH
    DCR typical @ +20 °C56 mOhm
    DCR maximum @ +20 °C65 mOhm
    Irms (DC, 40 °C rise)3 A
    Isat3 A
    SRF typical100 MHz
    K-factor2771
    MountingSurface mount
    Operating temperature-40 °C to +125 °C
    QualificationAEC-Q200
    RoHSCompliant, -R suffix
    Data sheetEaton Technical Data ELX1072

    Mechanical Drawing

    MPIA2010V1-1R0-R mechanical dimensions and pad layout

    Drawing reproduced from Eaton Technical Data ELX1072: outline with
    rated mm dimensions, pad layout and marking.

    What the Numbers Mean

    A molded automotive power inductor with a soft saturation curve: as current rises the inductance droops instead of collapsing, so a converter keeps control through a load step. The body is molded around the winding, which contains the field.

    At 3 A the winding dissipates about 0.504 W in copper using the typical DCR of 56 mOhm. That is the DC floor of the loss budget – ripple and core loss come on top.

    The core stores about 4.5 uJ at the saturation point, which is the energy available to bridge a load step.

    Self-resonance is 100 MHz typical. Keep the operating band, and the harmonics that carry energy, below it.

    The K-factor of 2771 converts inductance and ripple into flux swing; read the core-loss curve at that amplitude.

    Within the MPIA2010V1 family this is value 3 of 5, in a range from 0.33 uH to 2.2 uH.

    Series Positioning

    The MPIA family is the automotive miniature power range: AEC-Q200 qualified, low profile, in sizes from 2 mm to 4 mm, with both typical and maximum DCR quoted for every row.

    • DCR is quoted at +20 °C; copper rises about 0.4 % per °C, so the hot loss is higher than the cold figure.
    • Typical applications: body electronics; central body control module; vehicle access control system; headlamps, tail lamps and interior lighting and led lighting; doors, window lift and seat control.
    • Design note: ripple from OCL, thermal from Irms, transient from Isat. Three numbers, three checks.

    Frequently Asked Questions

    Why two DCR columns?
    Typical and maximum. A guaranteed thermal design uses the maximum; a nominal efficiency calculation can use the typical.

    Why two DCR columns?
    Typical and maximum. A guaranteed thermal design uses the maximum; a nominal efficiency calculation can use the typical.

    Is the part shielded?
    The molded body encloses the winding, so the external field is small enough for dense layouts.