Eaton MPIA2512V3-4R7-R 4.7 uH Inductor, Isat 1.9 A
Eaton MPIA2512V3-4R7-R 4.7 uH Inductor, Isat 1.9 A

Eaton MPIA2512V3-4R7-R 4.7 uH Inductor, Isat 1.9 A

Share
MPIA2512V3-4R7-R: automotive power inductor, 4.7 uH , 1.4 A Irms, Isat 1.9 A, DCR 196 mOhm.
    • Product Details
    • Download

    Eaton MPIA2512V3-4R7-R 4.7 uH Inductor, Isat 1.9 A

    MPIA2512V3-4R7-R at a glance: automotive power inductor, 4.7 uH , 1.4 A Irms, Isat 1.9 A, DCR 196 mOhm.

    Specification Table

    ParameterValue
    Orderable part numberMPIA2512V3-4R7-R
    Inductance4.7 uH
    FLL minimum (at Isat)2.63 uH
    DCR typical @ +20 °C196 mOhm
    DCR maximum @ +20 °C235 mOhm
    Irms (DC, 40 °C rise)1.4 A
    Isat1.9 A
    SRF typical29 MHz
    K-factor1890
    MountingSurface mount
    Operating temperature-40 °C to +125 °C
    QualificationAEC-Q200
    RoHSCompliant, -R suffix
    Data sheetEaton Technical Data ELX1487

    Dimensions and Pad Layout

    MPIA2512V3-4R7-R mechanical dimensions and pad layout

    Drawing reproduced from Eaton Technical Data ELX1487: outline with
    rated mm dimensions, pad layout and marking.

    How to Read These Ratings

    A molded automotive power inductor with a soft saturation curve: as current rises the inductance droops instead of collapsing, so a converter keeps control through a load step. The body is molded around the winding, which contains the field.

    At 1.4 A the winding dissipates about 0.384 W in copper using the typical DCR of 196 mOhm. That is the DC floor of the loss budget – ripple and core loss come on top.

    The core stores about 8.48 uJ at the saturation point, which is the energy available to bridge a load step.

    Self-resonance is 29 MHz typical. Keep the operating band, and the harmonics that carry energy, below it.

    The K-factor of 1890 converts inductance and ripple into flux swing; read the core-loss curve at that amplitude.

    Within the MPIA2512V3 family this is value 8 of 8, in a range from 0.33 uH to 4.7 uH.

    Series Positioning

    The MPIA family is the automotive miniature power range: AEC-Q200 qualified, low profile, in sizes from 2 mm to 4 mm, with both typical and maximum DCR quoted for every row.

    • DCR is quoted at +20 °C; copper rises about 0.4 % per °C, so the hot loss is higher than the cold figure.
    • Typical applications: body electronics; central body control module; vehicle access control system; headlamps, tail lamps and interior lighting and led lighting; doors, window lift and seat control.
    • Design note: ripple from OCL, thermal from Irms, transient from Isat. Three numbers, three checks.

    Frequently Asked Questions

    Why two DCR columns?
    Typical and maximum. A guaranteed thermal design uses the maximum; a nominal efficiency calculation can use the typical.

    Why two DCR columns?
    Typical and maximum. A guaranteed thermal design uses the maximum; a nominal efficiency calculation can use the typical.

    Why two DCR columns?
    Typical and maximum. A guaranteed thermal design uses the maximum; a nominal efficiency calculation can use the typical.

    Shenzhen Gaorunxin Technology Co., Ltd

    Online message

    Shenzhen Gaorunxin Technology Co., Ltd

    Related Products