Eaton MPIA4020V2-150-R 15 uH Inductor, Isat 1.8 A
Eaton MPIA4020V2-150-R 15 uH Inductor, Isat 1.8 A

Eaton MPIA4020V2-150-R 15 uH Inductor, Isat 1.8 A

Share
MPIA4020V2-150-R: automotive power inductor, 15 uH , 1.5 A Irms, Isat 1.8 A, DCR 320 mOhm.
    • Product Details
    • Download

    Eaton MPIA4020V2-150-R 15 uH Inductor, Isat 1.8 A

    MPIA4020V2-150-R at a glance: automotive power inductor, 15 uH , 1.5 A Irms, Isat 1.8 A, DCR 320 mOhm.

    Key Specifications

    ParameterValue
    Orderable part numberMPIA4020V2-150-R
    Inductance15 uH
    DCR typical @ +20 °C320 mOhm
    Irms (DC, 40 °C rise)1.5 A
    Isat1.8 A
    SRF typical384 MHz
    K-factor13
    MountingSurface mount
    Operating temperature-55 °C to +125 °C
    QualificationAEC-Q200
    RoHSCompliant, -R suffix
    Data sheetEaton Technical Data 10652

    Outline Drawing

    MPIA4020V2-150-R mechanical dimensions and pad layout

    Drawing reproduced from Eaton Technical Data 10652: outline with
    rated mm dimensions, pad layout and marking.

    What the Numbers Mean

    The part is built for automotive DC-DC stages: AEC-Q200 qualified, shielded, and characterised with both typical and maximum DCR so the loss budget can be built on either figure.

    At 1.5 A the winding dissipates about 0.72 W in copper using the typical DCR of 320 mOhm. That is the DC floor of the loss budget – ripple and core loss come on top.

    The core stores about 24.3 uJ at the saturation point, which is the energy available to bridge a load step.

    Self-resonance is 384 MHz typical. Keep the operating band, and the harmonics that carry energy, below it.

    The K-factor of 13 converts inductance and ripple into flux swing; read the core-loss curve at that amplitude.

    Within the MPIA4020V2 family this is value 15 of 16, in a range from 0.1 uH to 22 uH.

    Series Positioning

    The MPIA family is the automotive miniature power range: AEC-Q200 qualified, low profile, in sizes from 2 mm to 4 mm, with both typical and maximum DCR quoted for every row.

    • DCR is quoted at +20 °C; copper rises about 0.4 % per °C, so the hot loss is higher than the cold figure.
    • Typical applications: body electronics; central body control module; vehicle access control system; headlamps, tail lamps and interior lighting; doors, window lift and seat control.
    • Design note: ripple from OCL, thermal from Irms, transient from Isat. Three numbers, three checks.

    Frequently Asked Questions

    Is the part shielded?
    The molded body encloses the winding, so the external field is small enough for dense layouts.

    Why two DCR columns?
    Typical and maximum. A guaranteed thermal design uses the maximum; a nominal efficiency calculation can use the typical.

    How much inductance is left at rated current?
    The FLL column gives the inductance at saturation current. Ripple at full load should be calculated with FLL.