| Parameter | Value |
|---|---|
| Orderable part number | MPIA4020V2-4R7-R |
| Inductance | 4.7 uH |
| DCR typical @ +20 °C | 98 mOhm |
| Irms (DC, 40 °C rise) | 2.7 A |
| Isat | 3.2 A |
| SRF typical | 118 MHz |
| K-factor | 24 |
| Mounting | Surface mount |
| Operating temperature | -55 °C to +125 °C |
| Qualification | AEC-Q200 |
| RoHS | Compliant, -R suffix |
| Data sheet | Eaton Technical Data 10652 |

Drawing reproduced from Eaton Technical Data 10652: outline with
rated mm dimensions, pad layout and marking.
A molded automotive power inductor with a soft saturation curve: as current rises the inductance droops instead of collapsing, so a converter keeps control through a load step. The body is molded around the winding, which contains the field.
At 2.7 A the winding dissipates about 0.714 W in copper using the typical DCR of 98 mOhm. That is the DC floor of the loss budget – ripple and core loss come on top.
The core stores about 24.1 uJ at the saturation point, which is the energy available to bridge a load step.
Self-resonance is 118 MHz typical. Keep the operating band, and the harmonics that carry energy, below it.
The K-factor of 24 converts inductance and ripple into flux swing; read the core-loss curve at that amplitude.
Within the MPIA4020V2 family this is value 12 of 16, in a range from 0.1 uH to 22 uH.
The MPIA family is the automotive miniature power range: AEC-Q200 qualified, low profile, in sizes from 2 mm to 4 mm, with both typical and maximum DCR quoted for every row.
What is the difference between Irms and Isat?
Irms is the DC current for the rated temperature rise; Isat is the peak current at a defined inductance rolloff. A converter can exceed Irms briefly but must stay inside Isat.
What is the difference between Irms and Isat?
Irms is the DC current for the rated temperature rise; Isat is the peak current at a defined inductance rolloff. A converter can exceed Irms briefly but must stay inside Isat.
Why two DCR columns?
Typical and maximum. A guaranteed thermal design uses the maximum; a nominal efficiency calculation can use the typical.
Shenzhen Gaorunxin Technology Co., Ltd