| Parameter | Value |
|---|---|
| Orderable part number | MPIA4040R1-R47-R |
| Inductance | 0.47 uH |
| DCR typical @ +20 °C | 20 mOhm |
| Irms (DC, 40 °C rise) | 5.2 A |
| Isat | 11.5 A |
| K-factor | 1295 |
| Mounting | Surface mount |
| Operating temperature | -55 °C to +125 °C |
| Qualification | AEC-Q200 |
| RoHS | Compliant, -R suffix |
| Data sheet | Eaton Technical Data 10230 |

Drawing reproduced from Eaton Technical Data 10230: outline with
rated mm dimensions, pad layout and marking.
The part is built for automotive DC-DC stages: AEC-Q200 qualified, shielded, and characterised with both typical and maximum DCR so the loss budget can be built on either figure.
At 5.2 A the winding dissipates about 0.541 W in copper using the typical DCR of 20 mOhm. That is the DC floor of the loss budget – ripple and core loss come on top.
The core stores about 31.1 uJ at the saturation point, which is the energy available to bridge a load step.
The K-factor of 1295 converts inductance and ripple into flux swing; read the core-loss curve at that amplitude.
Within the MPIA4040R1 family this is value 5 of 11, in a range from 0.09 uH to 4.7 uH.
The MPIA family is the automotive miniature power range: AEC-Q200 qualified, low profile, in sizes from 2 mm to 4 mm, with both typical and maximum DCR quoted for every row.
How much inductance is left at rated current?
The FLL column gives the inductance at saturation current. Ripple at full load should be calculated with FLL.
What is the difference between Irms and Isat?
Irms is the DC current for the rated temperature rise; Isat is the peak current at a defined inductance rolloff. A converter can exceed Irms briefly but must stay inside Isat.
What is the difference between Irms and Isat?
Irms is the DC current for the rated temperature rise; Isat is the peak current at a defined inductance rolloff. A converter can exceed Irms briefly but must stay inside Isat.
Shenzhen Gaorunxin Technology Co., Ltd
Shenzhen Gaorunxin Technology Co., Ltd