| Parameter | Value |
|---|---|
| Orderable part number | MPIA4040R3-6R8-R |
| Inductance | 6.8 uH |
| DCR typical @ +20 °C | 120 mOhm |
| Irms (DC, 40 °C rise) | 2 A |
| Isat | 4.5 A |
| K-factor | 306 |
| Mounting | Surface mount |
| Operating temperature | -55 °C to +125 °C |
| Qualification | AEC-Q200 |
| RoHS | Compliant, -R suffix |
| Data sheet | Eaton Technical Data 10230 |

Drawing reproduced from Eaton Technical Data 10230: outline with
rated mm dimensions, pad layout and marking.
The part is built for automotive DC-DC stages: AEC-Q200 qualified, shielded, and characterised with both typical and maximum DCR so the loss budget can be built on either figure.
At 2 A the winding dissipates about 0.48 W in copper using the typical DCR of 120 mOhm. That is the DC floor of the loss budget – ripple and core loss come on top.
The core stores about 68.8 uJ at the saturation point, which is the energy available to bridge a load step.
The K-factor of 306 converts inductance and ripple into flux swing; read the core-loss curve at that amplitude.
Within the MPIA4040R3 family this is value 8 of 10, in a range from 0.22 uH to 15 uH.
The MPIA family is the automotive miniature power range: AEC-Q200 qualified, low profile, in sizes from 2 mm to 4 mm, with both typical and maximum DCR quoted for every row.
Is the part shielded?
The molded body encloses the winding, so the external field is small enough for dense layouts.
What is the difference between Irms and Isat?
Irms is the DC current for the rated temperature rise; Isat is the peak current at a defined inductance rolloff. A converter can exceed Irms briefly but must stay inside Isat.
Why two DCR columns?
Typical and maximum. A guaranteed thermal design uses the maximum; a nominal efficiency calculation can use the typical.
Shenzhen Gaorunxin Technology Co., Ltd