Eaton P4SMA110CA TVS Diode, 152 V Clamp
Eaton P4SMA110CA TVS Diode, 152 V Clamp

Eaton P4SMA110CA TVS Diode, 152 V Clamp

Share
P4SMA110CA: transient voltage suppressor diode, 94 V standoff, 152 V clamp, 2.7 A pulse, 400 W, bidirectional.
    • Product Details
    • Download

    Eaton P4SMA110CA TVS Diode, 152 V Clamp

    P4SMA110CA at a glance: transient voltage suppressor diode, 94 V standoff, 152 V clamp, 2.7 A pulse, 400 W, bidirectional.

    Specification Table

    ParameterValue
    Orderable part numberP4SMA110CA
    Standoff voltage (VR)94 V
    Leakage current at VR1 uA
    Breakdown voltage at IT105 V to 116 V
    Test current (IT)1 mA
    Clamping voltage at IPP152 V
    Peak pulse current2.7 A
    PolarityBidirectional
    Peak pulse power, 10/1000 us400 W
    PackageSMA (DO-214AC)
    MountingSurface mount
    Operating temperature-55 °C to +150 °C
    QualificationCommercial grade
    RoHSCompliant, halogen free
    Data sheetEaton Technical Data 11211

    Outline drawing, pad or lead geometry and the pulse derating curves are
    on the pages of Eaton Technical Data 11211; the package line above is the
    body the part is built in.

    What the Numbers Mean

    A TVS is chosen after the surge source is known. The pulse current in the table is the current the part can take, so the source impedance and the coupling network decide whether the clamp column is the number the protected circuit experiences.

    The breakdown window spans 10.48 percent, from 105 V to 116 V. Design against the minimum, because a part at the bottom of the window starts conducting first.

    At 94 V standing the leakage is at most 1 uA, so the part draws 0.094 mW on the rail. Small, but it is the number that matters on a battery input.

    Within the P4SMA family this is item 30 of 44 in the Eaton catalogue.

    Positioning in the Range

    Keep the ground connection on the same layer as the diode. A clamp that has to travel through a via to reach the return plane loses most of its advantage at the edge speeds an ESD event produces.

    • The standoff voltage is a DC limit. On an AC line the peak of the sine has to stay below it, which for a 120 V RMS line means a part rated well above 170 V.
    • The breakdown window is deliberately wide so that production spread does not leave parts conducting at the standoff voltage. Design to the minimum breakdown, not the typical.

    Frequently Asked Questions

    How much capacitance does it add?
    Enough to matter on a fast line. A 1500 W part can be several thousand picofarads, which is fine on a supply rail and not fine on a USB or Ethernet pair.

    Why is the clamp voltage higher than the breakdown voltage?
    The breakdown is measured at 1 mA; the clamp is measured at the full pulse current, which can be hundreds of amps. The dynamic resistance of the junction adds the difference, and that is why the two columns are never the same number.

    How do I pick the standoff voltage?
    Above the highest steady-state voltage the line can reach, including regulation, ripple and any temporary overvoltage the standard requires. Then check that the minimum breakdown voltage is still above that level, because production spread moves it down.

    Shenzhen Gaorunxin Technology Co., Ltd

    Online message

    Shenzhen Gaorunxin Technology Co., Ltd

    Related Products