Eaton P4SMA15A 12.8 V 400 W TVS Diode
Eaton P4SMA15A 12.8 V 400 W TVS Diode

Eaton P4SMA15A 12.8 V 400 W TVS Diode

Share
P4SMA15A: transient voltage suppressor diode, 12.8 V standoff, 21.2 V clamp, 19.3 A pulse, 400 W, unidirectional.
    • Product Details
    • Download

    Eaton P4SMA15A 12.8 V 400 W TVS Diode

    P4SMA15A at a glance: transient voltage suppressor diode, 12.8 V standoff, 21.2 V clamp, 19.3 A pulse, 400 W, unidirectional.

    Ratings at a Glance

    ParameterValue
    Orderable part numberP4SMA15A
    Standoff voltage (VR)12.8 V
    Leakage current at VR1 uA
    Breakdown voltage at IT14.3 V to 15.8 V
    Test current (IT)1 mA
    Clamping voltage at IPP21.2 V
    Peak pulse current19.3 A
    PolarityUnidirectional
    Peak pulse power, 10/1000 us400 W
    PackageSMA (DO-214AC)
    MountingSurface mount
    Operating temperature-55 °C to +150 °C
    QualificationCommercial grade
    RoHSCompliant, halogen free
    Data sheetEaton Technical Data 11211

    Outline drawing, pad or lead geometry and the pulse derating curves are
    on the pages of Eaton Technical Data 11211; the package line above is the
    body the part is built in.

    The Figures Explained

    These parts are avalanching junctions, so they clamp harder than a varistor and recover without the voltage drift a metal oxide part shows after a surge. The trade is capacitance and a sharper failure mode.

    The breakdown window spans 10.49 percent, from 14.3 V to 15.8 V. Design against the minimum, because a part at the bottom of the window starts conducting first.

    At 12.8 V standing the leakage is at most 1 uA, so the part draws 0.0128 mW on the rail. Small, but it is the number that matters on a battery input.

    Within the P4SMA family this is item 9 of 44 in the Eaton catalogue.

    What This Family Is For

    Place it on the protected side of any series impedance, not behind it. A TVS behind a common mode choke protects the choke, which is usually the opposite of what the design intends.

    • The standoff voltage is a DC limit. On an AC line the peak of the sine has to stay below it, which for a 120 V RMS line means a part rated well above 170 V.
    • The breakdown window is deliberately wide so that production spread does not leave parts conducting at the standoff voltage. Design to the minimum breakdown, not the typical.

    Frequently Asked Questions

    Why is the clamp voltage higher than the breakdown voltage?
    The breakdown is measured at 1 mA; the clamp is measured at the full pulse current, which can be hundreds of amps. The dynamic resistance of the junction adds the difference, and that is why the two columns are never the same number.

    How do I pick the standoff voltage?
    Above the highest steady-state voltage the line can reach, including regulation, ripple and any temporary overvoltage the standard requires. Then check that the minimum breakdown voltage is still above that level, because production spread moves it down.

    Unidirectional or bidirectional?
    Unidirectional on a DC rail, where the forward direction gives a low clamp for one polarity. Bidirectional on AC, on differential pairs and wherever the surge can arrive with either polarity.