Eaton P4SMA160CA TVS Diode, 219 V Clamp
Eaton P4SMA160CA TVS Diode, 219 V Clamp

Eaton P4SMA160CA TVS Diode, 219 V Clamp

Share
P4SMA160CA: transient voltage suppressor diode, 136 V standoff, 219 V clamp, 1.9 A pulse, 400 W, bidirectional.
    • Product Details
    • Download

    Eaton P4SMA160CA TVS Diode, 219 V Clamp

    P4SMA160CA at a glance: transient voltage suppressor diode, 136 V standoff, 219 V clamp, 1.9 A pulse, 400 W, bidirectional.

    Electrical Specifications

    ParameterValue
    Orderable part numberP4SMA160CA
    Standoff voltage (VR)136 V
    Leakage current at VR1 uA
    Breakdown voltage at IT152 V to 168 V
    Test current (IT)1 mA
    Clamping voltage at IPP219 V
    Peak pulse current1.9 A
    PolarityBidirectional
    Peak pulse power, 10/1000 us400 W
    PackageSMA (DO-214AC)
    MountingSurface mount
    Operating temperature-55 °C to +150 °C
    QualificationCommercial grade
    RoHSCompliant, halogen free
    Data sheetEaton Technical Data 11211

    Outline drawing, pad or lead geometry and the pulse derating curves are
    on the pages of Eaton Technical Data 11211; the package line above is the
    body the part is built in.

    What the Numbers Mean

    The peak pulse power rating is a 10/1000 microsecond figure: a 400 W part takes 400 W for one millisecond, not continuously. Shorter pulses allow more current, longer ones less, which is what the derating curves in the data sheet show.

    The breakdown window spans 10.53 percent, from 152 V to 168 V. Design against the minimum, because a part at the bottom of the window starts conducting first.

    At 136 V standing the leakage is at most 1 uA, so the part draws 0.136 mW on the rail. Small, but it is the number that matters on a battery input.

    Within the P4SMA family this is item 34 of 44 in the Eaton catalogue.

    Series Positioning

    Place it on the protected side of any series impedance, not behind it. A TVS behind a common mode choke protects the choke, which is usually the opposite of what the design intends.

    • The pulse current is quoted for one waveform. A different waveform changes the allowable current, and the derating curve, not the single number, is the guide.
    • The breakdown window is deliberately wide so that production spread does not leave parts conducting at the standoff voltage. Design to the minimum breakdown, not the typical.

    Frequently Asked Questions

    What happens if the surge exceeds the rating?
    The junction overheats and fails short, which then puts the full fault current through the board. That is why a fuse ahead of the suppressor is part of the protection, not an optional extra.

    How much capacitance does it add?
    Enough to matter on a fast line. A 1500 W part can be several thousand picofarads, which is fine on a supply rail and not fine on a USB or Ethernet pair.

    Does the peak pulse power rating apply to any surge?
    No. It is quoted for a 10/1000 microsecond waveform. A shorter pulse allows more current and a longer one less; the derating curve converts between them.