P4SMA200A: transient voltage suppressor diode, 171 V standoff, 274 V clamp, 1.5 A pulse, 400 W, unidirectional.
    • Product Details
    • Download

    Eaton P4SMA200A 171 V 400 W TVS Diode

    P4SMA200A at a glance: transient voltage suppressor diode, 171 V standoff, 274 V clamp, 1.5 A pulse, 400 W, unidirectional.

    Electrical Specifications

    ParameterValue
    Orderable part numberP4SMA200A
    Standoff voltage (VR)171 V
    Leakage current at VR1 uA
    Breakdown voltage at IT190 V to 210 V
    Test current (IT)1 mA
    Clamping voltage at IPP274 V
    Peak pulse current1.5 A
    PolarityUnidirectional
    Peak pulse power, 10/1000 us400 W
    PackageSMA (DO-214AC)
    MountingSurface mount
    Operating temperature-55 °C to +150 °C
    QualificationCommercial grade
    RoHSCompliant, halogen free
    Data sheetEaton Technical Data 11211

    Outline drawing, pad or lead geometry and the pulse derating curves are
    on the pages of Eaton Technical Data 11211; the package line above is the
    body the part is built in.

    How to Read These Ratings

    The standoff voltage has to sit above the highest steady state level on the line, including regulation and ripple. The breakdown voltage is then one diode drop above that, and the clamp is what the downstream circuit actually sees.

    The breakdown window spans 10.53 percent, from 190 V to 210 V. Design against the minimum, because a part at the bottom of the window starts conducting first.

    At 171 V standing the leakage is at most 1 uA, so the part draws 0.171 mW on the rail. Small, but it is the number that matters on a battery input.

    Within the P4SMA family this is item 37 of 44 in the Eaton catalogue.

    Where This Series Fits

    Keep the ground connection on the same layer as the diode. A clamp that has to travel through a via to reach the return plane loses most of its advantage at the edge speeds an ESD event produces.

    • A unidirectional part clamps a positive surge to its forward drop and a negative one to its breakdown. On an AC or bipolar signal that asymmetry is a design error, not a detail.
    • Bidirectional parts are two junctions back to back in one package. They clamp symmetrically, at the cost of roughly double the capacitance of a unidirectional part of the same die.

    Frequently Asked Questions

    What happens if the surge exceeds the rating?
    The junction overheats and fails short, which then puts the full fault current through the board. That is why a fuse ahead of the suppressor is part of the protection, not an optional extra.

    Unidirectional or bidirectional?
    Unidirectional on a DC rail, where the forward direction gives a low clamp for one polarity. Bidirectional on AC, on differential pairs and wherever the surge can arrive with either polarity.

    Why is the clamp voltage higher than the breakdown voltage?
    The breakdown is measured at 1 mA; the clamp is measured at the full pulse current, which can be hundreds of amps. The dynamic resistance of the junction adds the difference, and that is why the two columns are never the same number.