Eaton P4SMA220CA TVS Diode, 328 V Clamp
Eaton P4SMA220CA TVS Diode, 328 V Clamp

Eaton P4SMA220CA TVS Diode, 328 V Clamp

Share
P4SMA220CA: transient voltage suppressor diode, 185 V standoff, 328 V clamp, 1.3 A pulse, 400 W, bidirectional.
    • Product Details
    • Download

    Eaton P4SMA220CA TVS Diode, 328 V Clamp

    P4SMA220CA at a glance: transient voltage suppressor diode, 185 V standoff, 328 V clamp, 1.3 A pulse, 400 W, bidirectional.

    Electrical Specifications

    ParameterValue
    Orderable part numberP4SMA220CA
    Standoff voltage (VR)185 V
    Leakage current at VR1 uA
    Breakdown voltage at IT209 V to 231 V
    Test current (IT)1 mA
    Clamping voltage at IPP328 V
    Peak pulse current1.3 A
    PolarityBidirectional
    Peak pulse power, 10/1000 us400 W
    PackageSMA (DO-214AC)
    MountingSurface mount
    Operating temperature-55 °C to +150 °C
    QualificationCommercial grade
    RoHSCompliant, halogen free
    Data sheetEaton Technical Data 11211

    Outline drawing, pad or lead geometry and the pulse derating curves are
    on the pages of Eaton Technical Data 11211; the package line above is the
    body the part is built in.

    The Figures Explained

    The standoff voltage has to sit above the highest steady state level on the line, including regulation and ripple. The breakdown voltage is then one diode drop above that, and the clamp is what the downstream circuit actually sees.

    The breakdown window spans 10.53 percent, from 209 V to 231 V. Design against the minimum, because a part at the bottom of the window starts conducting first.

    At 185 V standing the leakage is at most 1 uA, so the part draws 0.185 mW on the rail. Small, but it is the number that matters on a battery input.

    Within the P4SMA family this is item 38 of 44 in the Eaton catalogue.

    What This Family Is For

    Place it on the protected side of any series impedance, not behind it. A TVS behind a common mode choke protects the choke, which is usually the opposite of what the design intends.

    • The standoff voltage is a DC limit. On an AC line the peak of the sine has to stay below it, which for a 120 V RMS line means a part rated well above 170 V.
    • The breakdown window is deliberately wide so that production spread does not leave parts conducting at the standoff voltage. Design to the minimum breakdown, not the typical.

    Frequently Asked Questions

    How do I pick the standoff voltage?
    Above the highest steady-state voltage the line can reach, including regulation, ripple and any temporary overvoltage the standard requires. Then check that the minimum breakdown voltage is still above that level, because production spread moves it down.

    Why is the clamp voltage higher than the breakdown voltage?
    The breakdown is measured at 1 mA; the clamp is measured at the full pulse current, which can be hundreds of amps. The dynamic resistance of the junction adds the difference, and that is why the two columns are never the same number.

    Does the peak pulse power rating apply to any surge?
    No. It is quoted for a 10/1000 microsecond waveform. A shorter pulse allows more current and a longer one less; the derating curve converts between them.