Eaton P4SMA24A 20.5 V 400 W TVS Diode
Eaton P4SMA24A 20.5 V 400 W TVS Diode

Eaton P4SMA24A 20.5 V 400 W TVS Diode

Share
P4SMA24A: transient voltage suppressor diode, 20.5 V standoff, 33.2 V clamp, 12.3 A pulse, 400 W, unidirectional.
    • Product Details
    • Download

    Eaton P4SMA24A 20.5 V 400 W TVS Diode

    P4SMA24A at a glance: transient voltage suppressor diode, 20.5 V standoff, 33.2 V clamp, 12.3 A pulse, 400 W, unidirectional.

    Key Specifications

    ParameterValue
    Orderable part numberP4SMA24A
    Standoff voltage (VR)20.5 V
    Leakage current at VR1 uA
    Breakdown voltage at IT22.8 V to 25.2 V
    Test current (IT)1 mA
    Clamping voltage at IPP33.2 V
    Peak pulse current12.3 A
    PolarityUnidirectional
    Peak pulse power, 10/1000 us400 W
    PackageSMA (DO-214AC)
    MountingSurface mount
    Operating temperature-55 °C to +150 °C
    QualificationCommercial grade
    RoHSCompliant, halogen free
    Data sheetEaton Technical Data 11211

    Outline drawing, pad or lead geometry and the pulse derating curves are
    on the pages of Eaton Technical Data 11211; the package line above is the
    body the part is built in.

    How to Read These Ratings

    The standoff voltage has to sit above the highest steady state level on the line, including regulation and ripple. The breakdown voltage is then one diode drop above that, and the clamp is what the downstream circuit actually sees.

    The breakdown window spans 10.53 percent, from 22.8 V to 25.2 V. Design against the minimum, because a part at the bottom of the window starts conducting first.

    At 20.5 V standing the leakage is at most 1 uA, so the part draws 0.0205 mW on the rail. Small, but it is the number that matters on a battery input.

    Within the P4SMA family this is item 14 of 44 in the Eaton catalogue.

    Positioning in the Range

    Keep the ground connection on the same layer as the diode. A clamp that has to travel through a via to reach the return plane loses most of its advantage at the edge speeds an ESD event produces.

    • The pulse current is quoted for one waveform. A different waveform changes the allowable current, and the derating curve, not the single number, is the guide.
    • The clamp column is measured at the rated pulse current. At a lower current the residual voltage is lower, which is why a part chosen for a small surge clamps better than its headline number suggests.

    Frequently Asked Questions

    How do I pick the standoff voltage?
    Above the highest steady-state voltage the line can reach, including regulation, ripple and any temporary overvoltage the standard requires. Then check that the minimum breakdown voltage is still above that level, because production spread moves it down.

    How much capacitance does it add?
    Enough to matter on a fast line. A 1500 W part can be several thousand picofarads, which is fine on a supply rail and not fine on a USB or Ethernet pair.

    Does the peak pulse power rating apply to any surge?
    No. It is quoted for a 10/1000 microsecond waveform. A shorter pulse allows more current and a longer one less; the derating curve converts between them.