Eaton P4SMA300CA Transient Voltage Suppressor 256 V
Eaton P4SMA300CA Transient Voltage Suppressor 256 V

Eaton P4SMA300CA Transient Voltage Suppressor 256 V

Share
P4SMA300CA: transient voltage suppressor diode, 256 V standoff, 414 V clamp, 1 A pulse, 400 W, bidirectional.
    • Product Details
    • Download

    Eaton P4SMA300CA Transient Voltage Suppressor 256 V

    P4SMA300CA at a glance: transient voltage suppressor diode, 256 V standoff, 414 V clamp, 1 A pulse, 400 W, bidirectional.

    Electrical Specifications

    ParameterValue
    Orderable part numberP4SMA300CA
    Standoff voltage (VR)256 V
    Leakage current at VR1 uA
    Breakdown voltage at IT285 V to 315 V
    Test current (IT)1 mA
    Clamping voltage at IPP414 V
    Peak pulse current1 A
    PolarityBidirectional
    Peak pulse power, 10/1000 us400 W
    PackageSMA (DO-214AC)
    MountingSurface mount
    Operating temperature-55 °C to +150 °C
    QualificationCommercial grade
    RoHSCompliant, halogen free
    Data sheetEaton Technical Data 11211

    Outline drawing, pad or lead geometry and the pulse derating curves are
    on the pages of Eaton Technical Data 11211; the package line above is the
    body the part is built in.

    Reading the Data Sheet

    A transient voltage suppressor is a diode biased so that it stays off at the working voltage and breaks down in a surge. The three numbers that decide whether it fits are the standoff voltage, the breakdown window and the clamping voltage at the pulse current you expect.

    The breakdown window spans 10.53 percent, from 285 V to 315 V. Design against the minimum, because a part at the bottom of the window starts conducting first.

    At 256 V standing the leakage is at most 1 uA, so the part draws 0.256 mW on the rail. Small, but it is the number that matters on a battery input.

    Within the P4SMA family this is item 41 of 44 in the Eaton catalogue.

    What This Family Is For

    Keep the ground connection on the same layer as the diode. A clamp that has to travel through a via to reach the return plane loses most of its advantage at the edge speeds an ESD event produces.

    • The pulse current is quoted for one waveform. A different waveform changes the allowable current, and the derating curve, not the single number, is the guide.
    • The clamp column is measured at the rated pulse current. At a lower current the residual voltage is lower, which is why a part chosen for a small surge clamps better than its headline number suggests.

    Frequently Asked Questions

    What happens if the surge exceeds the rating?
    The junction overheats and fails short, which then puts the full fault current through the board. That is why a fuse ahead of the suppressor is part of the protection, not an optional extra.

    Unidirectional or bidirectional?
    Unidirectional on a DC rail, where the forward direction gives a low clamp for one polarity. Bidirectional on AC, on differential pairs and wherever the surge can arrive with either polarity.

    Does the peak pulse power rating apply to any surge?
    No. It is quoted for a 10/1000 microsecond waveform. A shorter pulse allows more current and a longer one less; the derating curve converts between them.

    Shenzhen Gaorunxin Technology Co., Ltd

    Online message

    Shenzhen Gaorunxin Technology Co., Ltd

    Related Products