Eaton P4SMA30CA TVS Diode, 41.4 V Clamp
Eaton P4SMA30CA TVS Diode, 41.4 V Clamp

Eaton P4SMA30CA TVS Diode, 41.4 V Clamp

Share
P4SMA30CA: transient voltage suppressor diode, 25.6 V standoff, 41.4 V clamp, 9.9 A pulse, 400 W, bidirectional.
    • Product Details
    • Download

    Eaton P4SMA30CA TVS Diode, 41.4 V Clamp

    P4SMA30CA at a glance: transient voltage suppressor diode, 25.6 V standoff, 41.4 V clamp, 9.9 A pulse, 400 W, bidirectional.

    Ratings at a Glance

    ParameterValue
    Orderable part numberP4SMA30CA
    Standoff voltage (VR)25.6 V
    Leakage current at VR1 uA
    Breakdown voltage at IT28.5 V to 31.5 V
    Test current (IT)1 mA
    Clamping voltage at IPP41.4 V
    Peak pulse current9.9 A
    PolarityBidirectional
    Peak pulse power, 10/1000 us400 W
    PackageSMA (DO-214AC)
    MountingSurface mount
    Operating temperature-55 °C to +150 °C
    QualificationCommercial grade
    RoHSCompliant, halogen free
    Data sheetEaton Technical Data 11211

    Outline drawing, pad or lead geometry and the pulse derating curves are
    on the pages of Eaton Technical Data 11211; the package line above is the
    body the part is built in.

    Reading the Data Sheet

    The peak pulse power rating is a 10/1000 microsecond figure: a 400 W part takes 400 W for one millisecond, not continuously. Shorter pulses allow more current, longer ones less, which is what the derating curves in the data sheet show.

    The breakdown window spans 10.53 percent, from 28.5 V to 31.5 V. Design against the minimum, because a part at the bottom of the window starts conducting first.

    At 25.6 V standing the leakage is at most 1 uA, so the part draws 0.0256 mW on the rail. Small, but it is the number that matters on a battery input.

    Within the P4SMA family this is item 16 of 44 in the Eaton catalogue.

    Series Positioning

    Keep the ground connection on the same layer as the diode. A clamp that has to travel through a via to reach the return plane loses most of its advantage at the edge speeds an ESD event produces.

    • The standoff voltage is a DC limit. On an AC line the peak of the sine has to stay below it, which for a 120 V RMS line means a part rated well above 170 V.
    • The breakdown window is deliberately wide so that production spread does not leave parts conducting at the standoff voltage. Design to the minimum breakdown, not the typical.

    Frequently Asked Questions

    Does the peak pulse power rating apply to any surge?
    No. It is quoted for a 10/1000 microsecond waveform. A shorter pulse allows more current and a longer one less; the derating curve converts between them.

    Why is the clamp voltage higher than the breakdown voltage?
    The breakdown is measured at 1 mA; the clamp is measured at the full pulse current, which can be hundreds of amps. The dynamic resistance of the junction adds the difference, and that is why the two columns are never the same number.

    What happens if the surge exceeds the rating?
    The junction overheats and fails short, which then puts the full fault current through the board. That is why a fuse ahead of the suppressor is part of the protection, not an optional extra.

    Shenzhen Gaorunxin Technology Co., Ltd

    Online message

    Shenzhen Gaorunxin Technology Co., Ltd

    Related Products