P4SMA33CA: transient voltage suppressor diode, 28.2 V standoff, 45.7 V clamp, 9 A pulse, 400 W, bidirectional.
    • Product Details
    • Download

    Eaton P4SMA33CA Transient Voltage Suppressor 28.2 V

    P4SMA33CA at a glance: transient voltage suppressor diode, 28.2 V standoff, 45.7 V clamp, 9 A pulse, 400 W, bidirectional.

    Ratings at a Glance

    ParameterValue
    Orderable part numberP4SMA33CA
    Standoff voltage (VR)28.2 V
    Leakage current at VR1 uA
    Breakdown voltage at IT31.4 V to 34.7 V
    Test current (IT)1 mA
    Clamping voltage at IPP45.7 V
    Peak pulse current9 A
    PolarityBidirectional
    Peak pulse power, 10/1000 us400 W
    PackageSMA (DO-214AC)
    MountingSurface mount
    Operating temperature-55 °C to +150 °C
    QualificationCommercial grade
    RoHSCompliant, halogen free
    Data sheetEaton Technical Data 11211

    Outline drawing, pad or lead geometry and the pulse derating curves are
    on the pages of Eaton Technical Data 11211; the package line above is the
    body the part is built in.

    The Figures Explained

    A transient voltage suppressor is a diode biased so that it stays off at the working voltage and breaks down in a surge. The three numbers that decide whether it fits are the standoff voltage, the breakdown window and the clamping voltage at the pulse current you expect.

    The breakdown window spans 10.51 percent, from 31.4 V to 34.7 V. Design against the minimum, because a part at the bottom of the window starts conducting first.

    At 28.2 V standing the leakage is at most 1 uA, so the part draws 0.0282 mW on the rail. Small, but it is the number that matters on a battery input.

    Within the P4SMA family this is item 17 of 44 in the Eaton catalogue.

    Series Positioning

    The part goes across the line after the fuse, with the return path as short as the layout allows. Every centimetre of trace between the connector and the diode adds inductance, and the clamp the circuit sees is the diode clamp plus L di/dt.

    • The standoff voltage is a DC limit. On an AC line the peak of the sine has to stay below it, which for a 120 V RMS line means a part rated well above 170 V.
    • The clamp column is measured at the rated pulse current. At a lower current the residual voltage is lower, which is why a part chosen for a small surge clamps better than its headline number suggests.

    Frequently Asked Questions

    How much capacitance does it add?
    Enough to matter on a fast line. A 1500 W part can be several thousand picofarads, which is fine on a supply rail and not fine on a USB or Ethernet pair.

    Why is the clamp voltage higher than the breakdown voltage?
    The breakdown is measured at 1 mA; the clamp is measured at the full pulse current, which can be hundreds of amps. The dynamic resistance of the junction adds the difference, and that is why the two columns are never the same number.

    How do I pick the standoff voltage?
    Above the highest steady-state voltage the line can reach, including regulation, ripple and any temporary overvoltage the standard requires. Then check that the minimum breakdown voltage is still above that level, because production spread moves it down.