Eaton P4SMA350A 300 V 400 W TVS Diode
Eaton P4SMA350A 300 V 400 W TVS Diode

Eaton P4SMA350A 300 V 400 W TVS Diode

Share
P4SMA350A: transient voltage suppressor diode, 300 V standoff, 482 V clamp, 0.9 A pulse, 400 W, unidirectional.
    • Product Details
    • Download

    Eaton P4SMA350A 300 V 400 W TVS Diode

    P4SMA350A at a glance: transient voltage suppressor diode, 300 V standoff, 482 V clamp, 0.9 A pulse, 400 W, unidirectional.

    Specification Table

    ParameterValue
    Orderable part numberP4SMA350A
    Standoff voltage (VR)300 V
    Leakage current at VR1 uA
    Breakdown voltage at IT332 V to 368 V
    Test current (IT)1 mA
    Clamping voltage at IPP482 V
    Peak pulse current0.9 A
    PolarityUnidirectional
    Peak pulse power, 10/1000 us400 W
    PackageSMA (DO-214AC)
    MountingSurface mount
    Operating temperature-55 °C to +150 °C
    QualificationCommercial grade
    RoHSCompliant, halogen free
    Data sheetEaton Technical Data 11211

    Outline drawing, pad or lead geometry and the pulse derating curves are
    on the pages of Eaton Technical Data 11211; the package line above is the
    body the part is built in.

    The Figures Explained

    The standoff voltage has to sit above the highest steady state level on the line, including regulation and ripple. The breakdown voltage is then one diode drop above that, and the clamp is what the downstream circuit actually sees.

    The breakdown window spans 10.84 percent, from 332 V to 368 V. Design against the minimum, because a part at the bottom of the window starts conducting first.

    At 300 V standing the leakage is at most 1 uA, so the part draws 0.3 mW on the rail. Small, but it is the number that matters on a battery input.

    Within the P4SMA family this is item 42 of 44 in the Eaton catalogue.

    Positioning in the Range

    The part goes across the line after the fuse, with the return path as short as the layout allows. Every centimetre of trace between the connector and the diode adds inductance, and the clamp the circuit sees is the diode clamp plus L di/dt.

    • The standoff voltage is a DC limit. On an AC line the peak of the sine has to stay below it, which for a 120 V RMS line means a part rated well above 170 V.
    • Bidirectional parts are two junctions back to back in one package. They clamp symmetrically, at the cost of roughly double the capacitance of a unidirectional part of the same die.

    Frequently Asked Questions

    Why is the clamp voltage higher than the breakdown voltage?
    The breakdown is measured at 1 mA; the clamp is measured at the full pulse current, which can be hundreds of amps. The dynamic resistance of the junction adds the difference, and that is why the two columns are never the same number.

    What happens if the surge exceeds the rating?
    The junction overheats and fails short, which then puts the full fault current through the board. That is why a fuse ahead of the suppressor is part of the protection, not an optional extra.

    Does the peak pulse power rating apply to any surge?
    No. It is quoted for a 10/1000 microsecond waveform. A shorter pulse allows more current and a longer one less; the derating curve converts between them.