Eaton P4SMA6.8CA Transient Voltage Suppressor 5.8 V
Eaton P4SMA6.8CA Transient Voltage Suppressor 5.8 V

Eaton P4SMA6.8CA Transient Voltage Suppressor 5.8 V

Share
P4SMA6.8CA: transient voltage suppressor diode, 5.8 V standoff, 10.5 V clamp, 39 A pulse, 400 W, bidirectional.
    • Product Details
    • Download

    Eaton P4SMA6.8CA Transient Voltage Suppressor 5.8 V

    P4SMA6.8CA at a glance: transient voltage suppressor diode, 5.8 V standoff, 10.5 V clamp, 39 A pulse, 400 W, bidirectional.

    Ratings at a Glance

    ParameterValue
    Orderable part numberP4SMA6.8CA
    Standoff voltage (VR)5.8 V
    Leakage current at VR120 uA
    Breakdown voltage at IT6.45 V to 7.14 V
    Test current (IT)10 mA
    Clamping voltage at IPP10.5 V
    Peak pulse current39 A
    PolarityBidirectional
    Peak pulse power, 10/1000 us400 W
    PackageSMA (DO-214AC)
    MountingSurface mount
    Operating temperature-55 °C to +150 °C
    QualificationCommercial grade
    RoHSCompliant, halogen free
    Data sheetEaton Technical Data 11211

    Outline drawing, pad or lead geometry and the pulse derating curves are
    on the pages of Eaton Technical Data 11211; the package line above is the
    body the part is built in.

    How to Read These Ratings

    A transient voltage suppressor is a diode biased so that it stays off at the working voltage and breaks down in a surge. The three numbers that decide whether it fits are the standoff voltage, the breakdown window and the clamping voltage at the pulse current you expect.

    The breakdown window spans 10.7 percent, from 6.45 V to 7.14 V. Design against the minimum, because a part at the bottom of the window starts conducting first.

    At 5.8 V standing the leakage is at most 120 uA, so the part draws 0.696 mW on the rail. Small, but it is the number that matters on a battery input.

    Within the P4SMA family this is item 1 of 44 in the Eaton catalogue.

    Series Positioning

    Place it on the protected side of any series impedance, not behind it. A TVS behind a common mode choke protects the choke, which is usually the opposite of what the design intends.

    • A unidirectional part clamps a positive surge to its forward drop and a negative one to its breakdown. On an AC or bipolar signal that asymmetry is a design error, not a detail.
    • The clamp column is measured at the rated pulse current. At a lower current the residual voltage is lower, which is why a part chosen for a small surge clamps better than its headline number suggests.

    Frequently Asked Questions

    Does the peak pulse power rating apply to any surge?
    No. It is quoted for a 10/1000 microsecond waveform. A shorter pulse allows more current and a longer one less; the derating curve converts between them.

    How do I pick the standoff voltage?
    Above the highest steady-state voltage the line can reach, including regulation, ripple and any temporary overvoltage the standard requires. Then check that the minimum breakdown voltage is still above that level, because production spread moves it down.

    Unidirectional or bidirectional?
    Unidirectional on a DC rail, where the forward direction gives a low clamp for one polarity. Bidirectional on AC, on differential pairs and wherever the surge can arrive with either polarity.