Eaton P4SMA62CA TVS Diode, 85 V Clamp
Eaton P4SMA62CA TVS Diode, 85 V Clamp

Eaton P4SMA62CA TVS Diode, 85 V Clamp

Share
P4SMA62CA: transient voltage suppressor diode, 53 V standoff, 85 V clamp, 4.8 A pulse, 400 W, bidirectional.
    • Product Details
    • Download

    Eaton P4SMA62CA TVS Diode, 85 V Clamp

    P4SMA62CA at a glance: transient voltage suppressor diode, 53 V standoff, 85 V clamp, 4.8 A pulse, 400 W, bidirectional.

    Specification Table

    ParameterValue
    Orderable part numberP4SMA62CA
    Standoff voltage (VR)53 V
    Leakage current at VR1 uA
    Breakdown voltage at IT58.9 V to 65.1 V
    Test current (IT)1 mA
    Clamping voltage at IPP85 V
    Peak pulse current4.8 A
    PolarityBidirectional
    Peak pulse power, 10/1000 us400 W
    PackageSMA (DO-214AC)
    MountingSurface mount
    Operating temperature-55 °C to +150 °C
    QualificationCommercial grade
    RoHSCompliant, halogen free
    Data sheetEaton Technical Data 11211

    Outline drawing, pad or lead geometry and the pulse derating curves are
    on the pages of Eaton Technical Data 11211; the package line above is the
    body the part is built in.

    What the Numbers Mean

    A TVS is chosen after the surge source is known. The pulse current in the table is the current the part can take, so the source impedance and the coupling network decide whether the clamp column is the number the protected circuit experiences.

    The breakdown window spans 10.53 percent, from 58.9 V to 65.1 V. Design against the minimum, because a part at the bottom of the window starts conducting first.

    At 53 V standing the leakage is at most 1 uA, so the part draws 0.053 mW on the rail. Small, but it is the number that matters on a battery input.

    Within the P4SMA family this is item 24 of 44 in the Eaton catalogue.

    Where This Series Fits

    Keep the ground connection on the same layer as the diode. A clamp that has to travel through a via to reach the return plane loses most of its advantage at the edge speeds an ESD event produces.

    • The pulse current is quoted for one waveform. A different waveform changes the allowable current, and the derating curve, not the single number, is the guide.
    • Bidirectional parts are two junctions back to back in one package. They clamp symmetrically, at the cost of roughly double the capacitance of a unidirectional part of the same die.

    Frequently Asked Questions

    Why is the clamp voltage higher than the breakdown voltage?
    The breakdown is measured at 1 mA; the clamp is measured at the full pulse current, which can be hundreds of amps. The dynamic resistance of the junction adds the difference, and that is why the two columns are never the same number.

    What happens if the surge exceeds the rating?
    The junction overheats and fails short, which then puts the full fault current through the board. That is why a fuse ahead of the suppressor is part of the protection, not an optional extra.

    Does the peak pulse power rating apply to any surge?
    No. It is quoted for a 10/1000 microsecond waveform. A shorter pulse allows more current and a longer one less; the derating curve converts between them.