Eaton P4SMA7.5CA TVS Diode, 11.3 V Clamp
Eaton P4SMA7.5CA TVS Diode, 11.3 V Clamp

Eaton P4SMA7.5CA TVS Diode, 11.3 V Clamp

Share
P4SMA7.5CA: transient voltage suppressor diode, 6.4 V standoff, 11.3 V clamp, 36.3 A pulse, 400 W, bidirectional.
    • Product Details
    • Download

    Eaton P4SMA7.5CA TVS Diode, 11.3 V Clamp

    P4SMA7.5CA at a glance: transient voltage suppressor diode, 6.4 V standoff, 11.3 V clamp, 36.3 A pulse, 400 W, bidirectional.

    Specification Table

    ParameterValue
    Orderable part numberP4SMA7.5CA
    Standoff voltage (VR)6.4 V
    Leakage current at VR80 uA
    Breakdown voltage at IT7.13 V to 7.88 V
    Test current (IT)10 mA
    Clamping voltage at IPP11.3 V
    Peak pulse current36.3 A
    PolarityBidirectional
    Peak pulse power, 10/1000 us400 W
    PackageSMA (DO-214AC)
    MountingSurface mount
    Operating temperature-55 °C to +150 °C
    QualificationCommercial grade
    RoHSCompliant, halogen free
    Data sheetEaton Technical Data 11211

    Outline drawing, pad or lead geometry and the pulse derating curves are
    on the pages of Eaton Technical Data 11211; the package line above is the
    body the part is built in.

    How to Read These Ratings

    These parts are avalanching junctions, so they clamp harder than a varistor and recover without the voltage drift a metal oxide part shows after a surge. The trade is capacitance and a sharper failure mode.

    The breakdown window spans 10.52 percent, from 7.13 V to 7.88 V. Design against the minimum, because a part at the bottom of the window starts conducting first.

    At 6.4 V standing the leakage is at most 80 uA, so the part draws 0.512 mW on the rail. Small, but it is the number that matters on a battery input.

    Within the P4SMA family this is item 2 of 44 in the Eaton catalogue.

    Positioning in the Range

    Keep the ground connection on the same layer as the diode. A clamp that has to travel through a via to reach the return plane loses most of its advantage at the edge speeds an ESD event produces.

    • The pulse current is quoted for one waveform. A different waveform changes the allowable current, and the derating curve, not the single number, is the guide.
    • The clamp column is measured at the rated pulse current. At a lower current the residual voltage is lower, which is why a part chosen for a small surge clamps better than its headline number suggests.

    Frequently Asked Questions

    Why is the clamp voltage higher than the breakdown voltage?
    The breakdown is measured at 1 mA; the clamp is measured at the full pulse current, which can be hundreds of amps. The dynamic resistance of the junction adds the difference, and that is why the two columns are never the same number.

    How much capacitance does it add?
    Enough to matter on a fast line. A 1500 W part can be several thousand picofarads, which is fine on a supply rail and not fine on a USB or Ethernet pair.

    How do I pick the standoff voltage?
    Above the highest steady-state voltage the line can reach, including regulation, ripple and any temporary overvoltage the standard requires. Then check that the minimum breakdown voltage is still above that level, because production spread moves it down.

    Shenzhen Gaorunxin Technology Co., Ltd