Eaton P6SMB120CA Transient Voltage Suppressor 102 V
Eaton P6SMB120CA Transient Voltage Suppressor 102 V

Eaton P6SMB120CA Transient Voltage Suppressor 102 V

Share
P6SMB120CA: transient voltage suppressor diode, 102 V standoff, 165 V clamp, 3.7 A pulse, 600 W, bidirectional.
    • Product Details
    • Download

    Eaton P6SMB120CA Transient Voltage Suppressor 102 V

    P6SMB120CA at a glance: transient voltage suppressor diode, 102 V standoff, 165 V clamp, 3.7 A pulse, 600 W, bidirectional.

    Key Specifications

    ParameterValue
    Orderable part numberP6SMB120CA
    Standoff voltage (VR)102 V
    Leakage current at VR1 uA
    Breakdown voltage at IT114 V to 126 V
    Test current (IT)1 mA
    Clamping voltage at IPP165 V
    Peak pulse current3.7 A
    PolarityBidirectional
    Peak pulse power, 10/1000 us600 W
    PackageSMB (DO-214AA)
    MountingSurface mount
    Operating temperature-55 °C to +150 °C
    QualificationCommercial grade
    RoHSCompliant, halogen free
    Data sheetEaton Technical Data 11212

    Outline drawing, pad or lead geometry and the pulse derating curves are
    on the pages of Eaton Technical Data 11212; the package line above is the
    body the part is built in.

    The Figures Explained

    A TVS is chosen after the surge source is known. The pulse current in the table is the current the part can take, so the source impedance and the coupling network decide whether the clamp column is the number the protected circuit experiences.

    The breakdown window spans 10.53 percent, from 114 V to 126 V. Design against the minimum, because a part at the bottom of the window starts conducting first.

    At 102 V standing the leakage is at most 1 uA, so the part draws 0.102 mW on the rail. Small, but it is the number that matters on a battery input.

    Within the P6SMB family this is item 31 of 47 in the Eaton catalogue.

    Series Positioning

    The part goes across the line after the fuse, with the return path as short as the layout allows. Every centimetre of trace between the connector and the diode adds inductance, and the clamp the circuit sees is the diode clamp plus L di/dt.

    • The standoff voltage is a DC limit. On an AC line the peak of the sine has to stay below it, which for a 120 V RMS line means a part rated well above 170 V.
    • The breakdown window is deliberately wide so that production spread does not leave parts conducting at the standoff voltage. Design to the minimum breakdown, not the typical.

    Frequently Asked Questions

    What happens if the surge exceeds the rating?
    The junction overheats and fails short, which then puts the full fault current through the board. That is why a fuse ahead of the suppressor is part of the protection, not an optional extra.

    Why is the clamp voltage higher than the breakdown voltage?
    The breakdown is measured at 1 mA; the clamp is measured at the full pulse current, which can be hundreds of amps. The dynamic resistance of the junction adds the difference, and that is why the two columns are never the same number.

    Does the peak pulse power rating apply to any surge?
    No. It is quoted for a 10/1000 microsecond waveform. A shorter pulse allows more current and a longer one less; the derating curve converts between them.

    Shenzhen Gaorunxin Technology Co., Ltd

    Online message

    Shenzhen Gaorunxin Technology Co., Ltd

    Related Products