Eaton P6SMB130CA TVS Diode, 179 V Clamp
Eaton P6SMB130CA TVS Diode, 179 V Clamp

Eaton P6SMB130CA TVS Diode, 179 V Clamp

Share
P6SMB130CA: transient voltage suppressor diode, 111 V standoff, 179 V clamp, 3.4 A pulse, 600 W, bidirectional.
    • Product Details
    • Download

    Eaton P6SMB130CA TVS Diode, 179 V Clamp

    P6SMB130CA at a glance: transient voltage suppressor diode, 111 V standoff, 179 V clamp, 3.4 A pulse, 600 W, bidirectional.

    Electrical Specifications

    ParameterValue
    Orderable part numberP6SMB130CA
    Standoff voltage (VR)111 V
    Leakage current at VR1 uA
    Breakdown voltage at IT124 V to 137 V
    Test current (IT)1 mA
    Clamping voltage at IPP179 V
    Peak pulse current3.4 A
    PolarityBidirectional
    Peak pulse power, 10/1000 us600 W
    PackageSMB (DO-214AA)
    MountingSurface mount
    Operating temperature-55 °C to +150 °C
    QualificationCommercial grade
    RoHSCompliant, halogen free
    Data sheetEaton Technical Data 11212

    Outline drawing, pad or lead geometry and the pulse derating curves are
    on the pages of Eaton Technical Data 11212; the package line above is the
    body the part is built in.

    The Figures Explained

    The peak pulse power rating is a 10/1000 microsecond figure: a 400 W part takes 400 W for one millisecond, not continuously. Shorter pulses allow more current, longer ones less, which is what the derating curves in the data sheet show.

    The breakdown window spans 10.48 percent, from 124 V to 137 V. Design against the minimum, because a part at the bottom of the window starts conducting first.

    At 111 V standing the leakage is at most 1 uA, so the part draws 0.111 mW on the rail. Small, but it is the number that matters on a battery input.

    Within the P6SMB family this is item 32 of 47 in the Eaton catalogue.

    Where This Series Fits

    Keep the ground connection on the same layer as the diode. A clamp that has to travel through a via to reach the return plane loses most of its advantage at the edge speeds an ESD event produces.

    • A unidirectional part clamps a positive surge to its forward drop and a negative one to its breakdown. On an AC or bipolar signal that asymmetry is a design error, not a detail.
    • The clamp column is measured at the rated pulse current. At a lower current the residual voltage is lower, which is why a part chosen for a small surge clamps better than its headline number suggests.

    Frequently Asked Questions

    What happens if the surge exceeds the rating?
    The junction overheats and fails short, which then puts the full fault current through the board. That is why a fuse ahead of the suppressor is part of the protection, not an optional extra.

    Unidirectional or bidirectional?
    Unidirectional on a DC rail, where the forward direction gives a low clamp for one polarity. Bidirectional on AC, on differential pairs and wherever the surge can arrive with either polarity.

    Does the peak pulse power rating apply to any surge?
    No. It is quoted for a 10/1000 microsecond waveform. A shorter pulse allows more current and a longer one less; the derating curve converts between them.