Eaton P6SMB20CA TVS Diode, 27.7 V Clamp
Eaton P6SMB20CA TVS Diode, 27.7 V Clamp

Eaton P6SMB20CA TVS Diode, 27.7 V Clamp

Share
P6SMB20CA: transient voltage suppressor diode, 17.1 V standoff, 27.7 V clamp, 21.7 A pulse, 600 W, bidirectional.
    • Product Details
    • Download

    Eaton P6SMB20CA TVS Diode, 27.7 V Clamp

    P6SMB20CA at a glance: transient voltage suppressor diode, 17.1 V standoff, 27.7 V clamp, 21.7 A pulse, 600 W, bidirectional.

    Electrical Specifications

    ParameterValue
    Orderable part numberP6SMB20CA
    Standoff voltage (VR)17.1 V
    Leakage current at VR1 uA
    Breakdown voltage at IT19 V to 21 V
    Test current (IT)1 mA
    Clamping voltage at IPP27.7 V
    Peak pulse current21.7 A
    PolarityBidirectional
    Peak pulse power, 10/1000 us600 W
    PackageSMB (DO-214AA)
    MountingSurface mount
    Operating temperature-55 °C to +150 °C
    QualificationCommercial grade
    RoHSCompliant, halogen free
    Data sheetEaton Technical Data 11212

    Outline drawing, pad or lead geometry and the pulse derating curves are
    on the pages of Eaton Technical Data 11212; the package line above is the
    body the part is built in.

    Reading the Data Sheet

    These parts are avalanching junctions, so they clamp harder than a varistor and recover without the voltage drift a metal oxide part shows after a surge. The trade is capacitance and a sharper failure mode.

    The breakdown window spans 10.53 percent, from 19 V to 21 V. Design against the minimum, because a part at the bottom of the window starts conducting first.

    At 17.1 V standing the leakage is at most 1 uA, so the part draws 0.0171 mW on the rail. Small, but it is the number that matters on a battery input.

    Within the P6SMB family this is item 12 of 47 in the Eaton catalogue.

    What This Family Is For

    Place it on the protected side of any series impedance, not behind it. A TVS behind a common mode choke protects the choke, which is usually the opposite of what the design intends.

    • A unidirectional part clamps a positive surge to its forward drop and a negative one to its breakdown. On an AC or bipolar signal that asymmetry is a design error, not a detail.
    • The clamp column is measured at the rated pulse current. At a lower current the residual voltage is lower, which is why a part chosen for a small surge clamps better than its headline number suggests.

    Frequently Asked Questions

    How do I pick the standoff voltage?
    Above the highest steady-state voltage the line can reach, including regulation, ripple and any temporary overvoltage the standard requires. Then check that the minimum breakdown voltage is still above that level, because production spread moves it down.

    Unidirectional or bidirectional?
    Unidirectional on a DC rail, where the forward direction gives a low clamp for one polarity. Bidirectional on AC, on differential pairs and wherever the surge can arrive with either polarity.

    Why is the clamp voltage higher than the breakdown voltage?
    The breakdown is measured at 1 mA; the clamp is measured at the full pulse current, which can be hundreds of amps. The dynamic resistance of the junction adds the difference, and that is why the two columns are never the same number.

    Shenzhen Gaorunxin Technology Co., Ltd