Eaton P6SMB250A 214 V 600 W TVS Diode
Eaton P6SMB250A 214 V 600 W TVS Diode

Eaton P6SMB250A 214 V 600 W TVS Diode

Share
P6SMB250A: transient voltage suppressor diode, 214 V standoff, 344 V clamp, 1.8 A pulse, 600 W, unidirectional.
    • Product Details
    • Download

    Eaton P6SMB250A 214 V 600 W TVS Diode

    P6SMB250A at a glance: transient voltage suppressor diode, 214 V standoff, 344 V clamp, 1.8 A pulse, 600 W, unidirectional.

    Key Specifications

    ParameterValue
    Orderable part numberP6SMB250A
    Standoff voltage (VR)214 V
    Leakage current at VR1 uA
    Breakdown voltage at IT237 V to 263 V
    Test current (IT)1 mA
    Clamping voltage at IPP344 V
    Peak pulse current1.8 A
    PolarityUnidirectional
    Peak pulse power, 10/1000 us600 W
    PackageSMB (DO-214AA)
    MountingSurface mount
    Operating temperature-55 °C to +150 °C
    QualificationCommercial grade
    RoHSCompliant, halogen free
    Data sheetEaton Technical Data 11212

    Outline drawing, pad or lead geometry and the pulse derating curves are
    on the pages of Eaton Technical Data 11212; the package line above is the
    body the part is built in.

    How to Read These Ratings

    The peak pulse power rating is a 10/1000 microsecond figure: a 400 W part takes 400 W for one millisecond, not continuously. Shorter pulses allow more current, longer ones less, which is what the derating curves in the data sheet show.

    The breakdown window spans 10.97 percent, from 237 V to 263 V. Design against the minimum, because a part at the bottom of the window starts conducting first.

    At 214 V standing the leakage is at most 1 uA, so the part draws 0.214 mW on the rail. Small, but it is the number that matters on a battery input.

    Within the P6SMB family this is item 39 of 47 in the Eaton catalogue.

    What This Family Is For

    The part goes across the line after the fuse, with the return path as short as the layout allows. Every centimetre of trace between the connector and the diode adds inductance, and the clamp the circuit sees is the diode clamp plus L di/dt.

    • The pulse current is quoted for one waveform. A different waveform changes the allowable current, and the derating curve, not the single number, is the guide.
    • The clamp column is measured at the rated pulse current. At a lower current the residual voltage is lower, which is why a part chosen for a small surge clamps better than its headline number suggests.

    Frequently Asked Questions

    Unidirectional or bidirectional?
    Unidirectional on a DC rail, where the forward direction gives a low clamp for one polarity. Bidirectional on AC, on differential pairs and wherever the surge can arrive with either polarity.

    What happens if the surge exceeds the rating?
    The junction overheats and fails short, which then puts the full fault current through the board. That is why a fuse ahead of the suppressor is part of the protection, not an optional extra.

    How do I pick the standoff voltage?
    Above the highest steady-state voltage the line can reach, including regulation, ripple and any temporary overvoltage the standard requires. Then check that the minimum breakdown voltage is still above that level, because production spread moves it down.

    Shenzhen Gaorunxin Technology Co., Ltd

    Online message

    Shenzhen Gaorunxin Technology Co., Ltd

    Related Products