Eaton P6SMB300A 256 V 600 W TVS Diode
Eaton P6SMB300A 256 V 600 W TVS Diode

Eaton P6SMB300A 256 V 600 W TVS Diode

Share
P6SMB300A: transient voltage suppressor diode, 256 V standoff, 414 V clamp, 1.5 A pulse, 600 W, unidirectional.
    • Product Details
    • Download

    Eaton P6SMB300A 256 V 600 W TVS Diode

    P6SMB300A at a glance: transient voltage suppressor diode, 256 V standoff, 414 V clamp, 1.5 A pulse, 600 W, unidirectional.

    Ratings at a Glance

    ParameterValue
    Orderable part numberP6SMB300A
    Standoff voltage (VR)256 V
    Leakage current at VR1 uA
    Breakdown voltage at IT285 V to 315 V
    Test current (IT)1 mA
    Clamping voltage at IPP414 V
    Peak pulse current1.5 A
    PolarityUnidirectional
    Peak pulse power, 10/1000 us600 W
    PackageSMB (DO-214AA)
    MountingSurface mount
    Operating temperature-55 °C to +150 °C
    QualificationCommercial grade
    RoHSCompliant, halogen free
    Data sheetEaton Technical Data 11212

    Outline drawing, pad or lead geometry and the pulse derating curves are
    on the pages of Eaton Technical Data 11212; the package line above is the
    body the part is built in.

    What the Numbers Mean

    The standoff voltage has to sit above the highest steady state level on the line, including regulation and ripple. The breakdown voltage is then one diode drop above that, and the clamp is what the downstream circuit actually sees.

    The breakdown window spans 10.53 percent, from 285 V to 315 V. Design against the minimum, because a part at the bottom of the window starts conducting first.

    At 256 V standing the leakage is at most 1 uA, so the part draws 0.256 mW on the rail. Small, but it is the number that matters on a battery input.

    Within the P6SMB family this is item 40 of 47 in the Eaton catalogue.

    Series Positioning

    Place it on the protected side of any series impedance, not behind it. A TVS behind a common mode choke protects the choke, which is usually the opposite of what the design intends.

    • The pulse current is quoted for one waveform. A different waveform changes the allowable current, and the derating curve, not the single number, is the guide.
    • Bidirectional parts are two junctions back to back in one package. They clamp symmetrically, at the cost of roughly double the capacitance of a unidirectional part of the same die.

    Frequently Asked Questions

    Does the peak pulse power rating apply to any surge?
    No. It is quoted for a 10/1000 microsecond waveform. A shorter pulse allows more current and a longer one less; the derating curve converts between them.

    How much capacitance does it add?
    Enough to matter on a fast line. A 1500 W part can be several thousand picofarads, which is fine on a supply rail and not fine on a USB or Ethernet pair.

    Why is the clamp voltage higher than the breakdown voltage?
    The breakdown is measured at 1 mA; the clamp is measured at the full pulse current, which can be hundreds of amps. The dynamic resistance of the junction adds the difference, and that is why the two columns are never the same number.

    Shenzhen Gaorunxin Technology Co., Ltd

    Online message

    Shenzhen Gaorunxin Technology Co., Ltd

    Related Products