Eaton P6SMB300CA TVS Diode, 414 V Clamp
Eaton P6SMB300CA TVS Diode, 414 V Clamp

Eaton P6SMB300CA TVS Diode, 414 V Clamp

Share
P6SMB300CA: transient voltage suppressor diode, 256 V standoff, 414 V clamp, 1.5 A pulse, 600 W, bidirectional.
    • Product Details
    • Download

    Eaton P6SMB300CA TVS Diode, 414 V Clamp

    P6SMB300CA at a glance: transient voltage suppressor diode, 256 V standoff, 414 V clamp, 1.5 A pulse, 600 W, bidirectional.

    Specification Table

    ParameterValue
    Orderable part numberP6SMB300CA
    Standoff voltage (VR)256 V
    Leakage current at VR1 uA
    Breakdown voltage at IT285 V to 315 V
    Test current (IT)1 mA
    Clamping voltage at IPP414 V
    Peak pulse current1.5 A
    PolarityBidirectional
    Peak pulse power, 10/1000 us600 W
    PackageSMB (DO-214AA)
    MountingSurface mount
    Operating temperature-55 °C to +150 °C
    QualificationCommercial grade
    RoHSCompliant, halogen free
    Data sheetEaton Technical Data 11212

    Outline drawing, pad or lead geometry and the pulse derating curves are
    on the pages of Eaton Technical Data 11212; the package line above is the
    body the part is built in.

    How to Read These Ratings

    A TVS is chosen after the surge source is known. The pulse current in the table is the current the part can take, so the source impedance and the coupling network decide whether the clamp column is the number the protected circuit experiences.

    The breakdown window spans 10.53 percent, from 285 V to 315 V. Design against the minimum, because a part at the bottom of the window starts conducting first.

    At 256 V standing the leakage is at most 1 uA, so the part draws 0.256 mW on the rail. Small, but it is the number that matters on a battery input.

    Within the P6SMB family this is item 40 of 47 in the Eaton catalogue.

    What This Family Is For

    Keep the ground connection on the same layer as the diode. A clamp that has to travel through a via to reach the return plane loses most of its advantage at the edge speeds an ESD event produces.

    • A unidirectional part clamps a positive surge to its forward drop and a negative one to its breakdown. On an AC or bipolar signal that asymmetry is a design error, not a detail.
    • The breakdown window is deliberately wide so that production spread does not leave parts conducting at the standoff voltage. Design to the minimum breakdown, not the typical.

    Frequently Asked Questions

    How much capacitance does it add?
    Enough to matter on a fast line. A 1500 W part can be several thousand picofarads, which is fine on a supply rail and not fine on a USB or Ethernet pair.

    Unidirectional or bidirectional?
    Unidirectional on a DC rail, where the forward direction gives a low clamp for one polarity. Bidirectional on AC, on differential pairs and wherever the surge can arrive with either polarity.

    How do I pick the standoff voltage?
    Above the highest steady-state voltage the line can reach, including regulation, ripple and any temporary overvoltage the standard requires. Then check that the minimum breakdown voltage is still above that level, because production spread moves it down.

    Shenzhen Gaorunxin Technology Co., Ltd

    Online message

    Shenzhen Gaorunxin Technology Co., Ltd

    Related Products