Eaton P6SMB400CA TVS Diode, 548 V Clamp
Eaton P6SMB400CA TVS Diode, 548 V Clamp

Eaton P6SMB400CA TVS Diode, 548 V Clamp

Share
P6SMB400CA: transient voltage suppressor diode, 342 V standoff, 548 V clamp, 1.1 A pulse, 600 W, bidirectional.
    • Product Details
    • Download

    Eaton P6SMB400CA TVS Diode, 548 V Clamp

    P6SMB400CA at a glance: transient voltage suppressor diode, 342 V standoff, 548 V clamp, 1.1 A pulse, 600 W, bidirectional.

    Key Specifications

    ParameterValue
    Orderable part numberP6SMB400CA
    Standoff voltage (VR)342 V
    Leakage current at VR1 uA
    Breakdown voltage at IT380 V to 420 V
    Test current (IT)1 mA
    Clamping voltage at IPP548 V
    Peak pulse current1.1 A
    PolarityBidirectional
    Peak pulse power, 10/1000 us600 W
    PackageSMB (DO-214AA)
    MountingSurface mount
    Operating temperature-55 °C to +150 °C
    QualificationCommercial grade
    RoHSCompliant, halogen free
    Data sheetEaton Technical Data 11212

    Outline drawing, pad or lead geometry and the pulse derating curves are
    on the pages of Eaton Technical Data 11212; the package line above is the
    body the part is built in.

    Reading the Data Sheet

    A TVS is chosen after the surge source is known. The pulse current in the table is the current the part can take, so the source impedance and the coupling network decide whether the clamp column is the number the protected circuit experiences.

    The breakdown window spans 10.53 percent, from 380 V to 420 V. Design against the minimum, because a part at the bottom of the window starts conducting first.

    At 342 V standing the leakage is at most 1 uA, so the part draws 0.342 mW on the rail. Small, but it is the number that matters on a battery input.

    Within the P6SMB family this is item 42 of 47 in the Eaton catalogue.

    What This Family Is For

    Place it on the protected side of any series impedance, not behind it. A TVS behind a common mode choke protects the choke, which is usually the opposite of what the design intends.

    • A unidirectional part clamps a positive surge to its forward drop and a negative one to its breakdown. On an AC or bipolar signal that asymmetry is a design error, not a detail.
    • The breakdown window is deliberately wide so that production spread does not leave parts conducting at the standoff voltage. Design to the minimum breakdown, not the typical.

    Frequently Asked Questions

    How do I pick the standoff voltage?
    Above the highest steady-state voltage the line can reach, including regulation, ripple and any temporary overvoltage the standard requires. Then check that the minimum breakdown voltage is still above that level, because production spread moves it down.

    Unidirectional or bidirectional?
    Unidirectional on a DC rail, where the forward direction gives a low clamp for one polarity. Bidirectional on AC, on differential pairs and wherever the surge can arrive with either polarity.

    Why is the clamp voltage higher than the breakdown voltage?
    The breakdown is measured at 1 mA; the clamp is measured at the full pulse current, which can be hundreds of amps. The dynamic resistance of the junction adds the difference, and that is why the two columns are never the same number.

    Shenzhen Gaorunxin Technology Co., Ltd

    Online message

    Shenzhen Gaorunxin Technology Co., Ltd