Eaton P6SMB510CA Transient Voltage Suppressor 434 V
Eaton P6SMB510CA Transient Voltage Suppressor 434 V

Eaton P6SMB510CA Transient Voltage Suppressor 434 V

Share
P6SMB510CA: transient voltage suppressor diode, 434 V standoff, 698 V clamp, 0.9 A pulse, 600 W, bidirectional.
    • Product Details
    • Download

    Eaton P6SMB510CA Transient Voltage Suppressor 434 V

    P6SMB510CA at a glance: transient voltage suppressor diode, 434 V standoff, 698 V clamp, 0.9 A pulse, 600 W, bidirectional.

    Electrical Specifications

    ParameterValue
    Orderable part numberP6SMB510CA
    Standoff voltage (VR)434 V
    Leakage current at VR1 uA
    Breakdown voltage at IT485 V to 535 V
    Test current (IT)1 mA
    Clamping voltage at IPP698 V
    Peak pulse current0.9 A
    PolarityBidirectional
    Peak pulse power, 10/1000 us600 W
    PackageSMB (DO-214AA)
    MountingSurface mount
    Operating temperature-55 °C to +150 °C
    QualificationCommercial grade
    RoHSCompliant, halogen free
    Data sheetEaton Technical Data 11212

    Outline drawing, pad or lead geometry and the pulse derating curves are
    on the pages of Eaton Technical Data 11212; the package line above is the
    body the part is built in.

    What the Numbers Mean

    A transient voltage suppressor is a diode biased so that it stays off at the working voltage and breaks down in a surge. The three numbers that decide whether it fits are the standoff voltage, the breakdown window and the clamping voltage at the pulse current you expect.

    The breakdown window spans 10.31 percent, from 485 V to 535 V. Design against the minimum, because a part at the bottom of the window starts conducting first.

    At 434 V standing the leakage is at most 1 uA, so the part draws 0.434 mW on the rail. Small, but it is the number that matters on a battery input.

    Within the P6SMB family this is item 45 of 47 in the Eaton catalogue.

    Where This Series Fits

    Keep the ground connection on the same layer as the diode. A clamp that has to travel through a via to reach the return plane loses most of its advantage at the edge speeds an ESD event produces.

    • The pulse current is quoted for one waveform. A different waveform changes the allowable current, and the derating curve, not the single number, is the guide.
    • The breakdown window is deliberately wide so that production spread does not leave parts conducting at the standoff voltage. Design to the minimum breakdown, not the typical.

    Frequently Asked Questions

    How do I pick the standoff voltage?
    Above the highest steady-state voltage the line can reach, including regulation, ripple and any temporary overvoltage the standard requires. Then check that the minimum breakdown voltage is still above that level, because production spread moves it down.

    What happens if the surge exceeds the rating?
    The junction overheats and fails short, which then puts the full fault current through the board. That is why a fuse ahead of the suppressor is part of the protection, not an optional extra.

    Does the peak pulse power rating apply to any surge?
    No. It is quoted for a 10/1000 microsecond waveform. A shorter pulse allows more current and a longer one less; the derating curve converts between them.

    Shenzhen Gaorunxin Technology Co., Ltd

    Online message

    Shenzhen Gaorunxin Technology Co., Ltd

    Related Products