Eaton P6SMB56CA Transient Voltage Suppressor 47.8 V
Eaton P6SMB56CA Transient Voltage Suppressor 47.8 V

Eaton P6SMB56CA Transient Voltage Suppressor 47.8 V

Share
P6SMB56CA: transient voltage suppressor diode, 47.8 V standoff, 77 V clamp, 7.9 A pulse, 600 W, bidirectional.
    • Product Details
    • Download

    Eaton P6SMB56CA Transient Voltage Suppressor 47.8 V

    P6SMB56CA at a glance: transient voltage suppressor diode, 47.8 V standoff, 77 V clamp, 7.9 A pulse, 600 W, bidirectional.

    Key Specifications

    ParameterValue
    Orderable part numberP6SMB56CA
    Standoff voltage (VR)47.8 V
    Leakage current at VR1 uA
    Breakdown voltage at IT53.2 V to 58.8 V
    Test current (IT)1 mA
    Clamping voltage at IPP77 V
    Peak pulse current7.9 A
    PolarityBidirectional
    Peak pulse power, 10/1000 us600 W
    PackageSMB (DO-214AA)
    MountingSurface mount
    Operating temperature-55 °C to +150 °C
    QualificationCommercial grade
    RoHSCompliant, halogen free
    Data sheetEaton Technical Data 11212

    Outline drawing, pad or lead geometry and the pulse derating curves are
    on the pages of Eaton Technical Data 11212; the package line above is the
    body the part is built in.

    How to Read These Ratings

    A transient voltage suppressor is a diode biased so that it stays off at the working voltage and breaks down in a surge. The three numbers that decide whether it fits are the standoff voltage, the breakdown window and the clamping voltage at the pulse current you expect.

    The breakdown window spans 10.53 percent, from 53.2 V to 58.8 V. Design against the minimum, because a part at the bottom of the window starts conducting first.

    At 47.8 V standing the leakage is at most 1 uA, so the part draws 0.0478 mW on the rail. Small, but it is the number that matters on a battery input.

    Within the P6SMB family this is item 23 of 47 in the Eaton catalogue.

    What This Family Is For

    Place it on the protected side of any series impedance, not behind it. A TVS behind a common mode choke protects the choke, which is usually the opposite of what the design intends.

    • The standoff voltage is a DC limit. On an AC line the peak of the sine has to stay below it, which for a 120 V RMS line means a part rated well above 170 V.
    • The breakdown window is deliberately wide so that production spread does not leave parts conducting at the standoff voltage. Design to the minimum breakdown, not the typical.

    Frequently Asked Questions

    Unidirectional or bidirectional?
    Unidirectional on a DC rail, where the forward direction gives a low clamp for one polarity. Bidirectional on AC, on differential pairs and wherever the surge can arrive with either polarity.

    How do I pick the standoff voltage?
    Above the highest steady-state voltage the line can reach, including regulation, ripple and any temporary overvoltage the standard requires. Then check that the minimum breakdown voltage is still above that level, because production spread moves it down.

    What happens if the surge exceeds the rating?
    The junction overheats and fails short, which then puts the full fault current through the board. That is why a fuse ahead of the suppressor is part of the protection, not an optional extra.

    Shenzhen Gaorunxin Technology Co., Ltd