Eaton P6SMB600CA Transient Voltage Suppressor 512 V
Eaton P6SMB600CA Transient Voltage Suppressor 512 V

Eaton P6SMB600CA Transient Voltage Suppressor 512 V

Share
P6SMB600CA: transient voltage suppressor diode, 512 V standoff, 828 V clamp, 0.75 A pulse, 600 W, bidirectional.
    • Product Details
    • Download

    Eaton P6SMB600CA Transient Voltage Suppressor 512 V

    P6SMB600CA at a glance: transient voltage suppressor diode, 512 V standoff, 828 V clamp, 0.75 A pulse, 600 W, bidirectional.

    Specification Table

    ParameterValue
    Orderable part numberP6SMB600CA
    Standoff voltage (VR)512 V
    Leakage current at VR1 uA
    Breakdown voltage at IT570 V to 630 V
    Test current (IT)1 mA
    Clamping voltage at IPP828 V
    Peak pulse current0.75 A
    PolarityBidirectional
    Peak pulse power, 10/1000 us600 W
    PackageSMB (DO-214AA)
    MountingSurface mount
    Operating temperature-55 °C to +150 °C
    QualificationCommercial grade
    RoHSCompliant, halogen free
    Data sheetEaton Technical Data 11212

    Outline drawing, pad or lead geometry and the pulse derating curves are
    on the pages of Eaton Technical Data 11212; the package line above is the
    body the part is built in.

    What the Numbers Mean

    These parts are avalanching junctions, so they clamp harder than a varistor and recover without the voltage drift a metal oxide part shows after a surge. The trade is capacitance and a sharper failure mode.

    The breakdown window spans 10.53 percent, from 570 V to 630 V. Design against the minimum, because a part at the bottom of the window starts conducting first.

    At 512 V standing the leakage is at most 1 uA, so the part draws 0.512 mW on the rail. Small, but it is the number that matters on a battery input.

    Within the P6SMB family this is item 47 of 47 in the Eaton catalogue.

    What This Family Is For

    The part goes across the line after the fuse, with the return path as short as the layout allows. Every centimetre of trace between the connector and the diode adds inductance, and the clamp the circuit sees is the diode clamp plus L di/dt.

    • The standoff voltage is a DC limit. On an AC line the peak of the sine has to stay below it, which for a 120 V RMS line means a part rated well above 170 V.
    • The breakdown window is deliberately wide so that production spread does not leave parts conducting at the standoff voltage. Design to the minimum breakdown, not the typical.

    Frequently Asked Questions

    Does the peak pulse power rating apply to any surge?
    No. It is quoted for a 10/1000 microsecond waveform. A shorter pulse allows more current and a longer one less; the derating curve converts between them.

    How do I pick the standoff voltage?
    Above the highest steady-state voltage the line can reach, including regulation, ripple and any temporary overvoltage the standard requires. Then check that the minimum breakdown voltage is still above that level, because production spread moves it down.

    Why is the clamp voltage higher than the breakdown voltage?
    The breakdown is measured at 1 mA; the clamp is measured at the full pulse current, which can be hundreds of amps. The dynamic resistance of the junction adds the difference, and that is why the two columns are never the same number.

    Shenzhen Gaorunxin Technology Co., Ltd

    Online message

    Shenzhen Gaorunxin Technology Co., Ltd

    Related Products