Eaton P6SMB91CA TVS Diode, 125 V Clamp
Eaton P6SMB91CA TVS Diode, 125 V Clamp

Eaton P6SMB91CA TVS Diode, 125 V Clamp

Share
P6SMB91CA: transient voltage suppressor diode, 77.8 V standoff, 125 V clamp, 4.9 A pulse, 600 W, bidirectional.
    • Product Details
    • Download

    Eaton P6SMB91CA TVS Diode, 125 V Clamp

    P6SMB91CA at a glance: transient voltage suppressor diode, 77.8 V standoff, 125 V clamp, 4.9 A pulse, 600 W, bidirectional.

    Electrical Specifications

    ParameterValue
    Orderable part numberP6SMB91CA
    Standoff voltage (VR)77.8 V
    Leakage current at VR1 uA
    Breakdown voltage at IT86.5 V to 95.5 V
    Test current (IT)1 mA
    Clamping voltage at IPP125 V
    Peak pulse current4.9 A
    PolarityBidirectional
    Peak pulse power, 10/1000 us600 W
    PackageSMB (DO-214AA)
    MountingSurface mount
    Operating temperature-55 °C to +150 °C
    QualificationCommercial grade
    RoHSCompliant, halogen free
    Data sheetEaton Technical Data 11212

    Outline drawing, pad or lead geometry and the pulse derating curves are
    on the pages of Eaton Technical Data 11212; the package line above is the
    body the part is built in.

    What the Numbers Mean

    The peak pulse power rating is a 10/1000 microsecond figure: a 400 W part takes 400 W for one millisecond, not continuously. Shorter pulses allow more current, longer ones less, which is what the derating curves in the data sheet show.

    The breakdown window spans 10.4 percent, from 86.5 V to 95.5 V. Design against the minimum, because a part at the bottom of the window starts conducting first.

    At 77.8 V standing the leakage is at most 1 uA, so the part draws 0.0778 mW on the rail. Small, but it is the number that matters on a battery input.

    Within the P6SMB family this is item 28 of 47 in the Eaton catalogue.

    Where This Series Fits

    Place it on the protected side of any series impedance, not behind it. A TVS behind a common mode choke protects the choke, which is usually the opposite of what the design intends.

    • A unidirectional part clamps a positive surge to its forward drop and a negative one to its breakdown. On an AC or bipolar signal that asymmetry is a design error, not a detail.
    • The clamp column is measured at the rated pulse current. At a lower current the residual voltage is lower, which is why a part chosen for a small surge clamps better than its headline number suggests.

    Frequently Asked Questions

    Unidirectional or bidirectional?
    Unidirectional on a DC rail, where the forward direction gives a low clamp for one polarity. Bidirectional on AC, on differential pairs and wherever the surge can arrive with either polarity.

    How much capacitance does it add?
    Enough to matter on a fast line. A 1500 W part can be several thousand picofarads, which is fine on a supply rail and not fine on a USB or Ethernet pair.

    What happens if the surge exceeds the rating?
    The junction overheats and fails short, which then puts the full fault current through the board. That is why a fuse ahead of the suppressor is part of the protection, not an optional extra.