Eaton POEA2FB1V13W1X12 PoE Flyback Transformer, 13 W
Eaton POEA2FB1V13W1X12 PoE Flyback Transformer, 13 W

Eaton POEA2FB1V13W1X12 PoE Flyback Transformer, 13 W

Share
POEA2FB1V13W1X12: PoE transformer, 1:0.5:0.5 turns ratio, 13 W.
    • Product Details
    • Download

    Eaton POEA2FB1V13W1X12 PoE Flyback Transformer, 13 W

    POEA2FB1V13W1X12 at a glance: PoE transformer, 1:0.5:0.5 turns ratio, 13 W.

    Specification Table

    ParameterValue
    Orderable part numberPOEA2FB1V13W1X12
    Output power13 W
    OCL (primary inductance)127 uH
    SCL (saturated inductance)0.65 uH
    Isat1.2 A
    Turns ratio pri : sec : aux1:0.5:0.5
    Output configuration(1) x 12.0 V @ 1.1 A
    DCR primary199 mOhm
    DCR secondary 164 mOhm
    DCR secondary 2not fitted
    DCR auxiliary308 mOhm
    Schematic variantWinding arrangement 7
    Package14.2 x 17.75 x 12.7 mm
    MountingSurface mount
    Operating temperature-40 C to +125 C
    QualificationCommercial grade
    RoHSCompliant, -R suffix
    Data sheetEaton Technical Data ELX1267

    Outline drawing, winding arrangement and recommended pad layout are on
    page 2 of Eaton Technical Data ELX1267; the package line above gives the body size where
    the data sheet states it.

    How to Read These Ratings

    A PoE PD flyback transformer takes the 37 to 57 V on the cable and steps it down to the rails the powered device needs, with the isolation barrier in between. The turns ratio, the primary inductance and the saturation current are set by the controller and the power level, not chosen freely.

    At the 1.2 A saturation point the primary stores about 91.4 uJ, which sets the maximum energy per switching cycle.

    Within the POEA2FB1V13W1X12 family this is item 1 of 1 in the Eaton catalogue.

    Series Positioning

    The PoE range covers 3 W to 156 W of output in EFD15 to EPC46 cores, flyback and forward topologies, with schematic variants for the common controller families.

    • The isolation barrier is only as good as the board spacing around it. Check creepage on the footprint, not just the part rating.
    • Typical applications: lighting; industrial automation; security systems; voip phone systems; network and bluetooth access points.
    • Design note: check Isat at the maximum ambient, and remember that the auxiliary winding also carries current.

    Frequently Asked Questions

    Why is SCL quoted as well as OCL?
    OCL is the open-circuit inductance and SCL is the saturated value. The controller needs OCL to set the current ramp and SCL to know where the core runs out, and the gap between them is the usable current range.

    What does the schematic number mean?
    It refers to the winding arrangement drawing in the data sheet: which winding is primary, how many secondaries, and where the auxiliary sits. Two parts with the same power level and different schematic numbers are not interchangeable.

    Is the isolation reinforced?
    The transformer provides the isolation barrier for the PD; the data sheet states the test voltage. Whether that satisfies reinforced or basic isolation is a system-level question that also involves the board spacing.