| Parameter | Value |
|---|---|
| Orderable part number | POEA2FB1V14W1X14 |
| Output power | 14 W |
| OCL (primary inductance) | 127 uH |
| SCL (saturated inductance) | 2.5 uH |
| Isat | 1.7 A |
| Turns ratio pri : sec : aux | 1:0.333:0.208 |
| Output configuration | (1) x 14.0 V @ 1.0 A |
| DCR primary | 460 mOhm |
| DCR secondary 1 | 65 mOhm |
| DCR secondary 2 | not fitted |
| DCR auxiliary | 94 mOhm |
| Schematic variant | Winding arrangement 9 |
| Package | 14.2 x 17.75 x 12.7 mm |
| Mounting | Surface mount |
| Operating temperature | -40 C to +125 C |
| Qualification | Commercial grade |
| RoHS | Compliant, -R suffix |
| Data sheet | Eaton Technical Data ELX1267 |
Outline drawing, winding arrangement and recommended pad layout are on
page 2 of Eaton Technical Data ELX1267; the package line above gives the body size where
the data sheet states it.
A PoE PD flyback transformer takes the 37 to 57 V on the cable and steps it down to the rails the powered device needs, with the isolation barrier in between. The turns ratio, the primary inductance and the saturation current are set by the controller and the power level, not chosen freely.
At the 1.7 A saturation point the primary stores about 184 uJ, which sets the maximum energy per switching cycle.
Within the POEA2FB1V14W1X14 family this is item 1 of 1 in the Eaton catalogue.
The PoE range covers 3 W to 156 W of output in EFD15 to EPC46 cores, flyback and forward topologies, with schematic variants for the common controller families.
What does the schematic number mean?
It refers to the winding arrangement drawing in the data sheet: which winding is primary, how many secondaries, and where the auxiliary sits. Two parts with the same power level and different schematic numbers are not interchangeable.
Is the isolation reinforced?
The transformer provides the isolation barrier for the PD; the data sheet states the test voltage. Whether that satisfies reinforced or basic isolation is a system-level question that also involves the board spacing.
Is the isolation reinforced?