Eaton POEA2FB1V19W1X8 Flyback Transformer 1:0.25:0.389
Eaton POEA2FB1V19W1X8 Flyback Transformer 1:0.25:0.389

Eaton POEA2FB1V19W1X8 Flyback Transformer 1:0.25:0.389

Share
POEA2FB1V19W1X8: PoE transformer, 1:0.25:0.389 turns ratio, 19 W.
    • Product Details
    • Download

    Eaton POEA2FB1V19W1X8 Flyback Transformer 1:0.25:0.389

    POEA2FB1V19W1X8 at a glance: PoE transformer, 1:0.25:0.389 turns ratio, 19 W.

    Electrical Specifications

    ParameterValue
    Orderable part numberPOEA2FB1V19W1X8
    Output power19 W
    OCL (primary inductance)90 uH
    SCL (saturated inductance)1 uH
    Isat1.9 A
    Turns ratio pri : sec : aux1:0.25:0.389
    Output configuration(1) x 8.0 V @ 2.3 A
    DCR primary245 mOhm
    DCR secondary 120 mOhm
    DCR secondary 2not fitted
    DCR auxiliary245 mOhm
    Package14.2 x 17.75 x 12.7 mm
    MountingSurface mount
    Operating temperature-40 C to +125 C
    QualificationCommercial grade
    RoHSCompliant, -R suffix
    Data sheetEaton Technical Data ELX1267

    Outline drawing, winding arrangement and recommended pad layout are on
    page 2 of Eaton Technical Data ELX1267; the package line above gives the body size where
    the data sheet states it.

    The Figures Explained

    PoE transformers are wound for a specific controller family, which is why the schematic column matters: the same core and power level can be wound as 1:0.389 or 1:0.143 depending on the output rail.

    At the 1.9 A saturation point the primary stores about 162 uJ, which sets the maximum energy per switching cycle.

    Within the POEA2FB1V19W1X8 family this is item 1 of 1 in the Eaton catalogue.

    Positioning in the Range

    The PoE range covers 3 W to 156 W of output in EFD15 to EPC46 cores, flyback and forward topologies, with schematic variants for the common controller families.

    • The isolation barrier is only as good as the board spacing around it. Check creepage on the footprint, not just the part rating.
    • Typical applications: lighting; industrial automation; security systems; voip phone systems; network and bluetooth access points.
    • Design note: check Isat at the maximum ambient, and remember that the auxiliary winding also carries current.

    Frequently Asked Questions

    What decides the turns ratio?
    The controller and the output rail. A flyback with a given primary inductance needs a specific ratio to keep the duty cycle in range at the minimum input voltage, so the ratio is set by the design, not chosen for convenience.

    Why is SCL quoted as well as OCL?
    OCL is the open-circuit inductance and SCL is the saturated value. The controller needs OCL to set the current ramp and SCL to know where the core runs out, and the gap between them is the usable current range.

    Can I use a forward part in a flyback design?
    No. The two topologies need different turns ratios and different primary inductance, and a forward transformer has no gap for energy storage.