Eaton POEA2FB3V12W1X12 Power over Ethernet Transformer
Eaton POEA2FB3V12W1X12 Power over Ethernet Transformer

Eaton POEA2FB3V12W1X12 Power over Ethernet Transformer

Share
POEA2FB3V12W1X12: PoE transformer, 1:0.389:0.444 turns ratio, 12 W.
    • Product Details
    • Download

    Eaton POEA2FB3V12W1X12 Power over Ethernet Transformer

    POEA2FB3V12W1X12 at a glance: PoE transformer, 1:0.389:0.444 turns ratio, 12 W.

    Key Specifications

    ParameterValue
    Orderable part numberPOEA2FB3V12W1X12
    Output power12 W
    OCL (primary inductance)140 uH
    SCL (saturated inductance)1.3 uH
    Isat1.4 A
    Turns ratio pri : sec : aux1:0.389:0.444
    Output configuration(1) x 12.0 V @ 1.0 A
    DCR primary365 mOhm
    DCR secondary 140 mOhm
    DCR secondary 2not fitted
    DCR auxiliary290 mOhm
    Schematic variantWinding arrangement 3
    Package14.2 x 17.75 x 12.7 mm
    MountingSurface mount
    Operating temperature-40 C to +125 C
    QualificationCommercial grade
    RoHSCompliant, -R suffix
    Data sheetEaton Technical Data ELX1267

    Outline drawing, winding arrangement and recommended pad layout are on
    page 2 of Eaton Technical Data ELX1267; the package line above gives the body size where
    the data sheet states it.

    Reading the Data Sheet

    PoE transformers are wound for a specific controller family, which is why the schematic column matters: the same core and power level can be wound as 1:0.389 or 1:0.143 depending on the output rail.

    At the 1.4 A saturation point the primary stores about 137 uJ, which sets the maximum energy per switching cycle.

    Within the POEA2FB3V12W1X12 family this is item 1 of 1 in the Eaton catalogue.

    Where This Series Fits

    The PoE range covers 3 W to 156 W of output in EFD15 to EPC46 cores, flyback and forward topologies, with schematic variants for the common controller families.

    • The isolation barrier is only as good as the board spacing around it. Check creepage on the footprint, not just the part rating.
    • Typical applications: lighting; industrial automation; security systems; voip phone systems; network and bluetooth access points.
    • Design note: check Isat at the maximum ambient, and remember that the auxiliary winding also carries current.

    Frequently Asked Questions

    Is the isolation reinforced?
    The transformer provides the isolation barrier for the PD; the data sheet states the test voltage. Whether that satisfies reinforced or basic isolation is a system-level question that also involves the board spacing.

    What does the schematic number mean?
    It refers to the winding arrangement drawing in the data sheet: which winding is primary, how many secondaries, and where the auxiliary sits. Two parts with the same power level and different schematic numbers are not interchangeable.

    Is the isolation reinforced?
    The transformer provides the isolation barrier for the PD; the data sheet states the test voltage. Whether that satisfies reinforced or basic isolation is a system-level question that also involves the board spacing.