Eaton POEB1FB1V13W2X5 Flyback Transformer 1:0.143:0.143:0.31
Eaton POEB1FB1V13W2X5 Flyback Transformer 1:0.143:0.143:0.31

Eaton POEB1FB1V13W2X5 Flyback Transformer 1:0.143:0.143:0.31

Share
POEB1FB1V13W2X5: PoE transformer, 1:0.143:0.143:0.31 turns ratio, 13 W.
    • Product Details
    • Download

    Eaton POEB1FB1V13W2X5 Flyback Transformer 1:0.143:0.143:0.31

    POEB1FB1V13W2X5 at a glance: PoE transformer, 1:0.143:0.143:0.31 turns ratio, 13 W.

    Key Specifications

    ParameterValue
    Orderable part numberPOEB1FB1V13W2X5
    Output power13 W
    OCL (primary inductance)155 uH
    SCL (saturated inductance)2.5 uH
    Isat1 A
    Turns ratio pri : sec : aux1:0.143:0.143:0.31
    Output configuration(2) x 5.0 V
    DCR primary500 mOhm
    DCR secondary 1220 mOhm
    DCR secondary 216 mOhm
    DCR auxiliary270 mOhm
    Schematic variantWinding arrangement 2
    Package22.3 x 17.3 x 9 mm
    MountingSurface mount
    Operating temperature-40 C to +125 C
    QualificationCommercial grade
    RoHSCompliant, -R suffix
    Data sheetEaton Technical Data ELX1268

    Outline drawing, winding arrangement and recommended pad layout are on
    page 2 of Eaton Technical Data ELX1268; the package line above gives the body size where
    the data sheet states it.

    How to Read These Ratings

    A PoE PD flyback transformer takes the 37 to 57 V on the cable and steps it down to the rails the powered device needs, with the isolation barrier in between. The turns ratio, the primary inductance and the saturation current are set by the controller and the power level, not chosen freely.

    At the 1 A saturation point the primary stores about 77.5 uJ, which sets the maximum energy per switching cycle.

    Within the POEB1FB1V13W2X5 family this is item 1 of 1 in the Eaton catalogue.

    What This Family Is For

    The PoE range covers 3 W to 156 W of output in EFD15 to EPC46 cores, flyback and forward topologies, with schematic variants for the common controller families.

    • The isolation barrier is only as good as the board spacing around it. Check creepage on the footprint, not just the part rating.
    • Typical applications: lighting; industrial automation; security systems; voip phone systems; network and bluetooth access points.
    • Design note: check Isat at the maximum ambient, and remember that the auxiliary winding also carries current.

    Frequently Asked Questions

    Can I use a forward part in a flyback design?
    No. The two topologies need different turns ratios and different primary inductance, and a forward transformer has no gap for energy storage.

    Why is SCL quoted as well as OCL?
    OCL is the open-circuit inductance and SCL is the saturated value. The controller needs OCL to set the current ramp and SCL to know where the core runs out, and the gap between them is the usable current range.

    Can I use a forward part in a flyback design?
    No. The two topologies need different turns ratios and different primary inductance, and a forward transformer has no gap for energy storage.