Eaton POEB2FB1V30W2X5 Flyback Transformer 1:0.182:0.227:0.409
Eaton POEB2FB1V30W2X5 Flyback Transformer 1:0.182:0.227:0.409

Eaton POEB2FB1V30W2X5 Flyback Transformer 1:0.182:0.227:0.409

Share
POEB2FB1V30W2X5: PoE transformer, 1:0.182:0.227:0.409 turns ratio, 30 W.
    • Product Details
    • Download

    Eaton POEB2FB1V30W2X5 Flyback Transformer 1:0.182:0.227:0.409

    POEB2FB1V30W2X5 at a glance: PoE transformer, 1:0.182:0.227:0.409 turns ratio, 30 W.

    Ratings at a Glance

    ParameterValue
    Orderable part numberPOEB2FB1V30W2X5
    Output power30 W
    OCL (primary inductance)100 uH
    SCL (saturated inductance)1 uH
    Isat1 A
    Turns ratio pri : sec : aux1:0.182:0.227:0.409
    Output configuration(2) x 5.0 V
    DCR primary100 mOhm
    DCR secondary 17 mOhm
    DCR secondary 270 mOhm
    DCR auxiliary260 mOhm
    Schematic variantWinding arrangement 2
    Package29.3 x 21.8 x 12 mm
    MountingSurface mount
    Operating temperature-40 C to +125 C
    QualificationCommercial grade
    RoHSCompliant, -R suffix
    Data sheetEaton Technical Data ELX1269

    Outline drawing, winding arrangement and recommended pad layout are on
    page 2 of Eaton Technical Data ELX1269; the package line above gives the body size where
    the data sheet states it.

    How to Read These Ratings

    A PoE PD flyback transformer takes the 37 to 57 V on the cable and steps it down to the rails the powered device needs, with the isolation barrier in between. The turns ratio, the primary inductance and the saturation current are set by the controller and the power level, not chosen freely.

    At the 1 A saturation point the primary stores about 50 uJ, which sets the maximum energy per switching cycle.

    Within the POEB2FB1V30W2X5 family this is item 1 of 1 in the Eaton catalogue.

    Series Positioning

    The PoE range covers 3 W to 156 W of output in EFD15 to EPC46 cores, flyback and forward topologies, with schematic variants for the common controller families.

    • The isolation barrier is only as good as the board spacing around it. Check creepage on the footprint, not just the part rating.
    • Typical applications: lighting; industrial automation; security systems; voip phone systems; network and bluetooth access points.
    • Design note: check Isat at the maximum ambient, and remember that the auxiliary winding also carries current.

    Frequently Asked Questions

    Why is SCL quoted as well as OCL?
    OCL is the open-circuit inductance and SCL is the saturated value. The controller needs OCL to set the current ramp and SCL to know where the core runs out, and the gap between them is the usable current range.

    What does the schematic number mean?
    It refers to the winding arrangement drawing in the data sheet: which winding is primary, how many secondaries, and where the auxiliary sits. Two parts with the same power level and different schematic numbers are not interchangeable.

    Can I use a forward part in a flyback design?
    No. The two topologies need different turns ratios and different primary inductance, and a forward transformer has no gap for energy storage.