Eaton POEB2FB1V40W1X5 Power over Ethernet Transformer
Eaton POEB2FB1V40W1X5 Power over Ethernet Transformer

Eaton POEB2FB1V40W1X5 Power over Ethernet Transformer

Share
POEB2FB1V40W1X5: PoE transformer, 1:0.25:0.625 turns ratio, 40 W.
    • Product Details
    • Download

    Eaton POEB2FB1V40W1X5 Power over Ethernet Transformer

    POEB2FB1V40W1X5 at a glance: PoE transformer, 1:0.25:0.625 turns ratio, 40 W.

    Electrical Specifications

    ParameterValue
    Orderable part numberPOEB2FB1V40W1X5
    Output power40 W
    OCL (primary inductance)100 uH
    SCL (saturated inductance)2 uH
    Isat1 A
    Turns ratio pri : sec : aux1:0.25:0.625
    Output configuration(1) x 5.0 V @ 8.0 A
    DCR primary150 mOhm
    DCR secondary 111 mOhm
    DCR secondary 2not fitted
    DCR auxiliary215 mOhm
    Schematic variantWinding arrangement 3
    Package29.3 x 21.8 x 12 mm
    MountingSurface mount
    Operating temperature-40 C to +125 C
    QualificationCommercial grade
    RoHSCompliant, -R suffix
    Data sheetEaton Technical Data ELX1269

    Outline drawing, winding arrangement and recommended pad layout are on
    page 2 of Eaton Technical Data ELX1269; the package line above gives the body size where
    the data sheet states it.

    The Figures Explained

    This is a flyback transformer for Power over Ethernet powered devices: primary, secondary and an auxiliary winding for the controller supply, all on one bobbin with reinforced insulation between primary and secondary.

    At the 1 A saturation point the primary stores about 50 uJ, which sets the maximum energy per switching cycle.

    Within the POEB2FB1V40W1X5 family this is item 1 of 1 in the Eaton catalogue.

    Where This Series Fits

    The PoE range covers 3 W to 156 W of output in EFD15 to EPC46 cores, flyback and forward topologies, with schematic variants for the common controller families.

    • The isolation barrier is only as good as the board spacing around it. Check creepage on the footprint, not just the part rating.
    • Typical applications: lighting; industrial automation; security systems; voip phone systems; network and bluetooth access points.
    • Design note: check Isat at the maximum ambient, and remember that the auxiliary winding also carries current.

    Frequently Asked Questions

    What decides the turns ratio?
    The controller and the output rail. A flyback with a given primary inductance needs a specific ratio to keep the duty cycle in range at the minimum input voltage, so the ratio is set by the design, not chosen for convenience.

    Is the isolation reinforced?
    The transformer provides the isolation barrier for the PD; the data sheet states the test voltage. Whether that satisfies reinforced or basic isolation is a system-level question that also involves the board spacing.

    Can I use a forward part in a flyback design?
    No. The two topologies need different turns ratios and different primary inductance, and a forward transformer has no gap for energy storage.