| Parameter | Value |
|---|---|
| Orderable part number | POEB2FB1V40W1X5 |
| Output power | 40 W |
| OCL (primary inductance) | 100 uH |
| SCL (saturated inductance) | 2 uH |
| Isat | 1 A |
| Turns ratio pri : sec : aux | 1:0.25:0.625 |
| Output configuration | (1) x 5.0 V @ 8.0 A |
| DCR primary | 150 mOhm |
| DCR secondary 1 | 11 mOhm |
| DCR secondary 2 | not fitted |
| DCR auxiliary | 215 mOhm |
| Schematic variant | Winding arrangement 3 |
| Package | 29.3 x 21.8 x 12 mm |
| Mounting | Surface mount |
| Operating temperature | -40 C to +125 C |
| Qualification | Commercial grade |
| RoHS | Compliant, -R suffix |
| Data sheet | Eaton Technical Data ELX1269 |
Outline drawing, winding arrangement and recommended pad layout are on
page 2 of Eaton Technical Data ELX1269; the package line above gives the body size where
the data sheet states it.
This is a flyback transformer for Power over Ethernet powered devices: primary, secondary and an auxiliary winding for the controller supply, all on one bobbin with reinforced insulation between primary and secondary.
At the 1 A saturation point the primary stores about 50 uJ, which sets the maximum energy per switching cycle.
Within the POEB2FB1V40W1X5 family this is item 1 of 1 in the Eaton catalogue.
The PoE range covers 3 W to 156 W of output in EFD15 to EPC46 cores, flyback and forward topologies, with schematic variants for the common controller families.
What decides the turns ratio?
The controller and the output rail. A flyback with a given primary inductance needs a specific ratio to keep the duty cycle in range at the minimum input voltage, so the ratio is set by the design, not chosen for convenience.
Is the isolation reinforced?
The transformer provides the isolation barrier for the PD; the data sheet states the test voltage. Whether that satisfies reinforced or basic isolation is a system-level question that also involves the board spacing.
Can I use a forward part in a flyback design?
No. The two topologies need different turns ratios and different primary inductance, and a forward transformer has no gap for energy storage.
Shenzhen Gaorunxin Technology Co., Ltd
Shenzhen Gaorunxin Technology Co., Ltd