Eaton POEB3FB1V84W2X12 Power over Ethernet Transformer
Eaton POEB3FB1V84W2X12 Power over Ethernet Transformer

Eaton POEB3FB1V84W2X12 Power over Ethernet Transformer

Share
POEB3FB1V84W2X12: PoE transformer, 1:0.273:0.273:0.227 turns ratio, 84 W.
    • Product Details
    • Download

    Eaton POEB3FB1V84W2X12 Power over Ethernet Transformer

    POEB3FB1V84W2X12 at a glance: PoE transformer, 1:0.273:0.273:0.227 turns ratio, 84 W.

    Ratings at a Glance

    ParameterValue
    Orderable part numberPOEB3FB1V84W2X12
    Output power84 W
    OCL (primary inductance)17.5 uH
    SCL (saturated inductance)1 uH
    Isat22 A
    Turns ratio pri : sec : aux1:0.273:0.273:0.227
    Output configuration(2) x 12.0 V
    DCR primary85 mOhm
    DCR secondary 17 mOhm
    DCR secondary 235 mOhm
    DCR auxiliary100 mOhm
    Schematic variantWinding arrangement 2
    Package32.8 x 26.8 x 14.8 mm
    MountingSurface mount
    Operating temperature-40 C to +125 C
    QualificationCommercial grade
    RoHSCompliant, -R suffix
    Data sheetEaton Technical Data ELX1270

    Outline drawing, winding arrangement and recommended pad layout are on
    page 2 of Eaton Technical Data ELX1270; the package line above gives the body size where
    the data sheet states it.

    Reading the Data Sheet

    PoE transformers are wound for a specific controller family, which is why the schematic column matters: the same core and power level can be wound as 1:0.389 or 1:0.143 depending on the output rail.

    At the 22 A saturation point the primary stores about 4235 uJ, which sets the maximum energy per switching cycle.

    Within the POEB3FB1V84W2X12 family this is item 1 of 1 in the Eaton catalogue.

    Positioning in the Range

    The PoE range covers 3 W to 156 W of output in EFD15 to EPC46 cores, flyback and forward topologies, with schematic variants for the common controller families.

    • The isolation barrier is only as good as the board spacing around it. Check creepage on the footprint, not just the part rating.
    • Typical applications: lighting; industrial automation; security systems; voip phone systems; network and bluetooth access points.
    • Design note: check Isat at the maximum ambient, and remember that the auxiliary winding also carries current.

    Frequently Asked Questions

    What decides the turns ratio?
    The controller and the output rail. A flyback with a given primary inductance needs a specific ratio to keep the duty cycle in range at the minimum input voltage, so the ratio is set by the design, not chosen for convenience.

    Is the isolation reinforced?
    The transformer provides the isolation barrier for the PD; the data sheet states the test voltage. Whether that satisfies reinforced or basic isolation is a system-level question that also involves the board spacing.

    What decides the turns ratio?
    The controller and the output rail. A flyback with a given primary inductance needs a specific ratio to keep the duty cycle in range at the minimum input voltage, so the ratio is set by the design, not chosen for convenience.

    Shenzhen Gaorunxin Technology Co., Ltd

    Online message