Eaton POEB4FW1V156W1X12 PoE PD Transformer 156 W
Eaton POEB4FW1V156W1X12 PoE PD Transformer 156 W

Eaton POEB4FW1V156W1X12 PoE PD Transformer 156 W

Share
POEB4FW1V156W1X12: PoE transformer, 1:0.5:0.5 turns ratio, 156 W.
    • Product Details
    • Download

    Eaton POEB4FW1V156W1X12 PoE PD Transformer 156 W

    POEB4FW1V156W1X12 at a glance: PoE transformer, 1:0.5:0.5 turns ratio, 156 W.

    Electrical Specifications

    ParameterValue
    Orderable part numberPOEB4FW1V156W1X12
    Output power156 W
    OCL (primary inductance)100 uH
    Isat0.25 A
    Turns ratio pri : sec : aux1:0.5:0.5
    Output configuration(1) x 12.0 V @ 13.0 A
    DCR primary20 mOhm
    DCR secondary 14.25 mOhm
    DCR secondary 2250 mOhm
    DCR auxiliary1 mOhm
    Package36 x 33 x 14.5 mm
    MountingSurface mount
    Operating temperature-40 C to +125 C
    QualificationCommercial grade
    RoHSCompliant, -R suffix
    Data sheetEaton Technical Data ELX1272

    Outline drawing, winding arrangement and recommended pad layout are on
    page 2 of Eaton Technical Data ELX1272; the package line above gives the body size where
    the data sheet states it.

    Reading the Data Sheet

    This is a flyback transformer for Power over Ethernet powered devices: primary, secondary and an auxiliary winding for the controller supply, all on one bobbin with reinforced insulation between primary and secondary.

    At the 0.25 A saturation point the primary stores about 3.12 uJ, which sets the maximum energy per switching cycle.

    Within the POEB4FW1V156W1X12 family this is item 1 of 1 in the Eaton catalogue.

    Positioning in the Range

    The PoE range covers 3 W to 156 W of output in EFD15 to EPC46 cores, flyback and forward topologies, with schematic variants for the common controller families.

    • The isolation barrier is only as good as the board spacing around it. Check creepage on the footprint, not just the part rating.
    • Typical applications: lighting; industrial automation; security systems; voip phone systems; network and bluetooth access points.
    • Design note: check Isat at the maximum ambient, and remember that the auxiliary winding also carries current.

    Frequently Asked Questions

    Is the isolation reinforced?
    The transformer provides the isolation barrier for the PD; the data sheet states the test voltage. Whether that satisfies reinforced or basic isolation is a system-level question that also involves the board spacing.

    Can I use a forward part in a flyback design?
    No. The two topologies need different turns ratios and different primary inductance, and a forward transformer has no gap for energy storage.

    What does the schematic number mean?
    It refers to the winding arrangement drawing in the data sheet: which winding is primary, how many secondaries, and where the auxiliary sits. Two parts with the same power level and different schematic numbers are not interchangeable.