| Parameter | Value |
|---|---|
| Orderable part number | PS04LTVA1 |
| Rated voltage | 12 V max (5 V typ) |
| Clamping voltage, typical | 25 V |
| Trigger voltage, typical | 150 V |
| Capacitance at 1 MHz, typical | 0.05 pF |
| Capacitance at 1 MHz, maximum | 0.15 pF |
| Attenuation change, 0-6 GHz | -0.2 dB typical |
| Leakage current at 12 Vdc | max. 0.1 nA |
| ESD capability, IEC 61000-4-2 | 8 kV contact / 15 kV air |
| ESD pulse withstand | >1000 pulses |
| Channels | 1 |
| Package | 0402 (1005 metric) |
| Mounting | Surface mount |
| Operating temperature | -40 °C to +85 °C |
| Qualification | AEC-Q200 |
| RoHS | Compliant, halogen free |
| Data sheet | Eaton Technical Data 4083 |
Outline drawing, pad or lead geometry and the pulse derating curves are
on the pages of Eaton Technical Data 4083; the package line above is the
body the part is built in.
An ESD rating is a qualification, not a life count: IEC 61000-4-2 level 4 is 8 kV contact and 15 kV air, and the part is expected to survive that repeatedly because the energy per event is small.
At 0.05 pF the part is effectively invisible to a multi-gigabit pair: the reactance at 1 GHz is still in the hundreds of ohms, far above the differential impedance.
Within the PS04LTVA family this is item 1 of 1 in the Eaton catalogue.
The ground pin goes to the connector ground, not to a distant plane. The discharge returns through that connection, and a long path turns the clamp into a radiator.
Does the package matter?
It sets the capacitance and the thermal mass. The same die in a 0201 and a 0603 gives different surge capability, so the package is part of the electrical choice, not just the footprint.
Will it survive repeated strikes?
The datasheet quotes a pulse count at the qualification level, typically over a thousand at 8 kV contact. That is the number to compare against the events the port is expected to see.
Is the suppressor fast enough for a cable discharge?
The response is in the sub-nanosecond range because the structure is a junction, not a spark gap. What limits the protection is the layout, not the die.