| Parameter | Rating |
|---|---|
| Part number | S500-100-R |
| Rated current | 100 mA |
| End caps | silver-plated 32-125 mA, nickel-plated above |
| Maximum voltage drop | 2,800 mV |
| Breaking capacity | 35 A at 250 Vac, 290 A and 1,500 A on the higher ratings |
| Typical DC cold resistance | 18 Ω |
| AC interrupting rating | 35 A at 250 Vac |
| Design standard | IEC 60127-2 |
| Body | Glass tube, 5 x 20 mm |
| Voltage rating | 250 Vac |
| Element | single element |
| Typical melting I2t | 0.0013 A²s |
Typical places this fuse turns up:
What are the ratings of the S500-100-R?
100 mA continuous at 250 Vac, interrupting rating 35 A at 250 Vac.
Can the S500-100-R be used on a higher fault-current circuit?
No — its interrupting rating is 35 A at 250 Vac. Choose a part whose breaking capacity exceeds the prospective fault current.