Eaton S501-200-R 200 mA 250 Vac Ceramic Fast-Acting Fuse
Eaton S501-200-R 200 mA 250 Vac Ceramic Fast-Acting Fuse

Eaton S501-200-R 200 mA 250 Vac Ceramic Fast-Acting Fuse

Share
pEaton S501-200-R — 200 mA, 250 V, fast-acting ceramic cartridge fuse, 1,500 A at 250 Vac interrupting./p
    • Product Details
    • Download

    Eaton S501-200-R 200 mA 250 Vac Ceramic Fast-Acting Fuse

    The S501-200-R from Eaton carries 200 mA, rated 250 Vac, uses a fast-acting element, in a ceramic body.

    Technical Data

    ParameterRating
    Part numberS501-200-R
    Breaking capacity1,500 A at 250 Vac across the whole range
    Typical DC cold resistance6 Ω
    Design standardIEC 60127-2
    Typical melting I2t0.02 A²s
    Voltage rating250 Vac
    End capssilver-plated 50-400 mA, nickel-plated 500 mA-10 A
    Rated current200 mA
    Maximum voltage drop1,350 mV
    BodyCeramic tube, 5 x 20 mm
    AC interrupting rating1,500 A at 250 Vac
    Elementsingle element

    Practical Notes

    • Interrupting capability is 1,500 A at 250 Vac — confirm the circuit's prospective fault current stays below this.
    • Fast element suits resistive and semiconductor loads rather than motors with high inrush.
    • Because it opens within milliseconds, downstream semiconductors see less let-through energy.
    • Ceramic body holds higher breaking capacity than glass at the same footprint.
    • It is the usual choice where prospective fault current is high.
    • Working voltage must stay at or below 250 Vac; a lower-rated part is not a safe substitute.
    • Do not upsize beyond 200 mA to stop nuisance trips — fix the cause instead.

    Application Scenarios

    Common installation contexts include:

    • EV
    • power supply
    • surge
    • transformer

    Questions and Answers

    What are the ratings of the S501-200-R?

    200 mA continuous at 250 Vac, interrupting rating 1,500 A at 250 Vac.

    Is the S501-200-R fast-acting or time-delay?

    It is fast-acting. Expect it to open quickly on overload.

    Can the S501-200-R be used on a higher fault-current circuit?

    No — its interrupting rating is 1,500 A at 250 Vac. Choose a part whose breaking capacity exceeds the prospective fault current.