Eaton S506-1-R 1 A 250 Vac Time-Delay Glass Tube Fuse
Eaton S506-1-R 1 A 250 Vac Time-Delay Glass Tube Fuse

Eaton S506-1-R 1 A 250 Vac Time-Delay Glass Tube Fuse

Share
pEaton S506-1-R — 1 A, 250 V, time-delay glass cartridge fuse, 35 A at 250 Vac, 50 Hz interrupting./p
    • Product Details
    • Download

    Eaton S506-1-R 1 A 250 Vac Time-Delay Glass Tube Fuse

    Eaton S506-1-R 1 A 250 Vac Time-Delay Glass Tube Fuse belongs to the Eaton range. It carries 0.09 A, rated 250 Vac, uses a time-delay element, in a glass body.

    Technical Data

    ParameterRating
    ParameterValue
    Orderable part numberS506-1-R (BK- prefix = 100 pcs carton, BK1- = 1,000 pcs polybag)
    AgencycURus (E19180, JDYX2); SEMKO; VDE; BSI; IMQ; PSE (JET); KC; CCC
    Typical cold resistance0.0757 Ohm
    Design standardIEC 60127-1 and 60127-2
    Time-delay classT (time-lag)
    Interrupting rating35 A at 250 Vac, 50 Hz
    Body5 x 20 mm glass tube, nickel-plated brass end caps
    Watts at rated current0.09 W
    Melting I2t (typical)6.45 A2s
    On-state drop, typical87.5 mV at rated current
    Current rating1 A
    Voltage rating250 Vac

    Design Notes

    • Interrupting capability is 35 A at 250 Vac, 50 Hz — confirm the circuit's prospective fault current stays below this.
    • Time-delay element rides through motor starting and capacitive inrush without nuisance opening.
    • Startup surges of several times rated current are tolerated for a short window.
    • Glass body lets you inspect the element after a fault.
    • Best kept for lower fault-current circuits where visual diagnosis matters.
    • Working voltage must stay at or below 250 Vac; a lower-rated part is not a safe substitute.
    • Do not upsize beyond 0.09 A to stop nuisance trips — fix the cause instead.

    Where It Is Used

    Typical places this fuse turns up:

    • EV
    • surge
    • transformer

    Common Questions

    What are the ratings of the S506-1-R?

    0.09 A continuous at 250 Vac, interrupting rating 35 A at 250 Vac, 50 Hz.

    Is the S506-1-R fast-acting or time-delay?

    It is time-delay. It tolerates short inrush surges.

    Can the S506-1-R be used on a higher fault-current circuit?

    No — its interrupting rating is 35 A at 250 Vac, 50 Hz. Choose a part whose breaking capacity exceeds the prospective fault current.