| Parameter | Rating |
|---|---|
| Parameter | Value |
| Orderable part number | S506-2.5-R (BK- prefix = 100 pcs carton, BK1- = 1,000 pcs polybag) |
| Dissipation at rating | 0.18 W |
| Interrupting rating | 35 A at 250 Vac, 50 Hz |
| Typical DC cold resistance | 0.0255 Ohm |
| Body | 5 x 20 mm glass tube, nickel-plated brass end caps |
| Agency | cURus (E19180, JDYX2); SEMKO; VDE; BSI; IMQ; PSE (JET); KC; CCC |
| Typical voltage drop | 72.5 mV at rated current |
| Current rating | 2.5 A |
| Voltage rating | 250 Vac |
| Design standard | IEC 60127-1 and 60127-2 |
| Time-delay class | T (time-lag) |
| I2t, typical melting | 59.4 A2s |
Common installation contexts include:
What are the ratings of the S506-2.5-R?
2.5 A continuous at 250 Vac, interrupting rating 35 A at 250 Vac, 50 Hz.
Is the S506-2.5-R fast-acting or time-delay?
It is time-delay. It tolerates short inrush surges.
Can the S506-2.5-R be used on a higher fault-current circuit?
No — its interrupting rating is 35 A at 250 Vac, 50 Hz. Choose a part whose breaking capacity exceeds the prospective fault current.
Shenzhen Gaorunxin Technology Co., Ltd
Shenzhen Gaorunxin Technology Co., Ltd